NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09520 analyzed in May 2002.
NYC-WTC_000023363–000023371Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Data File C:\HPCHEM\1\DATA\MAY0302\9520 .D Vial: 21 Acq On 4 May 2002 9:41 am Operator: Sample GC/MS SCAN 4/22 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC
peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 8.167 336 341 371 rBV 2726248 6613803 100.00% 26.169% 2 9.954 532 536 552 rBV 29473 79996 1.21% 0.317% 3 12.190 775 780 796 rVB 1253133 2825918 42.73% 11.181% 4 14.792 1058 1064 1071 rVB 78476 155579 2.35% 0.616% 5 15.828 1171 1177 1193 rBV 1794112 3581609 54.15% 14.171%
6 21.134 1749 1756 1773 rBV 1913547 3942217 59.61% 15.598% 7 23.269 1982 1989 1994 rBV 77441 155140 2.35% 0.614% 8 25.578 2233 2241 2250 rBV2 1698100 3597384 54.39% 14.234% 9 33.633 3114 3120 3132 rBV2 1073973 2460483 37.20% 9.735% 10 37.866 3573 3582 3596 rBV2 636499 1861565 28.15% 7.366%
Sum of corrected areas: 25273694
9520.D GCMS0501.M Tue May 07 09:38:41 2002
NYC-WTC_000023366
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023122
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023148
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023345
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09518 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023076
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023327
Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09578 analyzed in May 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000022953
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043678
Calibration table for GC/MS analysis listing deuterated standards and their response values from April 24, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043726
Calibration data for GC/MS analysis of surrogate compounds including dichlorobenzenes and naphthalene from April 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043112
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE09395 with unknown compounds and surrogate data from May 9, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000013146
Calibration table listing response factors for deuterated standards and target compounds used in gas chromatography-mass spectrometry analysis.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044621
Calibration scan report for EPA Method 625 showing retention times and deviations for deuterated standards on April 25 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.
Filed in the same folder