NYC 9/11 Public Portal Document
ASBESTOS ABATEMENT
Part 1 - GENERAL
1.01 DESCRIPTION
A. The Contract Documents are as defined in the “Agreement”. The General Conditions shall apply
to all Work of this Section.
B. Work specified herein shall be the removal and disposal of asbestos containing non-friable
sealant materials and associated fill material and exterior window caulking materials (ACSM)
located at:
PS 92M, located at 222 West 134" Street, New York, N.Y.
The asbestos containing sealant material is a non-friable material that is primarily found as the
sealant applied to the exterior concrete structural columns and horizontal concrete members of
the building. The associated non-asbestos fill material is found underneath and is the surface on
which the sealant was applied. Asbestos containing exterior window frame caulking is found on
the windows of the school and is to be removed as part of this project only in areas where the
sealant overlaps the caulking. The sealant was applied as a waterproofing material.
It is the intention to remove all ACSM from the relevant structures affected by this project and to
dispose of this material, as asbestos containing in accordance with all applicable Federal, State
and local regulations, including proper disposal requirements.
In certain areas of the project where the window caulking is to be removed, the Contractor will
furnish and install a non-asbestos caulking material suitable in appearance, texture and service
application when and where directed by the Construction Manager.
1.02 SCOPE OF WORK
The Contractor is responsible for the confirmation of the actual total quantities of the work to be
perfomied prior to Bidding. Removal and disposal of asbestos containing exterior water sealant
in the Work Areas described in Drawings A6.0 & A6.1. A variance specific to this site utilizing
tent procedures within the work areas shall be applied for by the Contractor and approved by
NYCDEP prior to the start of abatement activities.
A. The Contractor shall perform the following work as described below:
SPECIFIC LOCATION .ASBESTOS Archileclural Noles
CONTAINING Drawing Reference
MATERIAL_________
Exterior Beams and Exterior Sealant and Drawings A6.0 and Remove and dispose
Columns on Entire associated non-asbestos A6.1 of as ACM
School Building cementitious fill and
window frame caulk
CITY_21 MCI 00_014563775
NYC-WTC_000454575
OCR can misread numbers and units. Confirm readings against the page image before using them.