NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
per matrix per analytical parameter (with the exception of corrosivity and ignitability).
10.3.4 Field Spikes
PCDDs and PAHs Field spikes are clean media used for sampling and pre-spiked with
i3Ci2-labeled compounds (similar to the target analytes) and used to evaluate overall
accuracy. The media will be spiked in the laboratory, sent out to the field with all sample
media, and returned to the laboratory for analysis.
Total Mercury In addition, during the background phase of the program, the accuracy
and precision of the mercury sampling and analysis method will be tested. Ambient air
samples will be collected at one location using a series of four carbon traps prespiked (50
ng/trap) with mercury. These samples will provide data on the accuracy and precision of
the method under actual field sampling condition. Following the background phase, one
field spike will be performed every other week.
10.3.5 Breakthrough Checks
Separate analyses of both front and back half portions of carbon traps for mercury will
be performed during the background phase to allow for an assessment of analyte
breakthrough. The breakthrough assessment will be performed on all stations during the
background phase. Breakthrough on the back half of the trap must be < 2% of the front
half of the trap or < 5 ng per trap. If breakthrough criteria are consistently met during the
background phase, subsequent measurement will be performed with the front and back
halves of the carbon traps combined for analyses.
10.3.6 Media Certification Checks
Media for all analyses collected a on time-integrated basis will be certified clean from
the laboratories. The certifications will be performed as batch checks and results will be
stored in the project files.
11.0 ANALYTICAL REQUIREMENTS
11.1 Analytical Methods
This section of the QAPP describes the analytical techniques that will be used by the
fixed laboratories to generate definitive data for the project. It documents the fixed
laboratory analytical methods that will be used to meet measurement performance criteria
and achieve the project-required quantitation limits for all contaminants of concern in the
specific matrices as identified on Tables 8-la-c.
11.1.1 Fixed Laboratory Analytical Methods and SOPs
Table 11-1 details the analytical methods that will be used in this investigation
71
CITY_21MC100_0 03239924
NYC-WTC_000446692
OCR can misread numbers and units. Confirm readings against the page image before using them.