NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 110 pages

QA Plan for Air Monitoring Program, Sept 2005

Machine-extracted title · confidence 55%

Quality Assurance Project Plan for environmental air monitoring and waste management at Greenwich and Thames sites; Sept 30, 2005.

NYC-WTC_000423885–000423994
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

10.3.4 Field Spikes

PCDDs and PAHs Field spikes are clean media used for sampling and pre-spiked with i3Ci2-labeled compounds (similar to the target analytes) and used to evaluate overall accuracy. The media will be spiked in the laboratory, sent out to the field with all sample media, and returned to the laboratory for analysis.

Total Mercury In addition, during the background phase of the program, the accuracy and precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the accuracy and precision of the method under actual field sampling condition. Following the background phase, one field spike will be performed every other week.

10.3.5 Breakthrough Checks

Separate analyses of both front and back half portions of carbon traps for mercury will be performed during the background phase to allow for an assessment of analyte breakthrough. The breakthrough assessment will be performed on all stations during the background phase. Breakthrough on the back half of the trap must be < 2% of the front half of the trap or < 5 ng per trap. If breakthrough criteria are consistently met during the background phase, subsequent measurement will be performed with the front and back halves of the carbon traps combined for analyses.

10.3.6 Media Certification Checks

Media for all analyses collected a on time-integrated basis will be certified clean from the laboratories. The certifications will be performed as batch checks and results will be stored in the project files.

11.0 ANALYTICAL REQUIREMENTS

11.1 Analytical Methods

This section of the QAPP describes the analytical techniques that will be used by the fixed laboratories to generate definitive data for the project. It documents the fixed laboratory analytical methods that will be used to meet measurement performance criteria and achieve the project-required quantitation limits for all contaminants of concern in the specific matrices as identified on Table 8-1.

11.1.1 Fixed Laboratory Analytical Methods and SOPs

Table 11-1 details the analytical methods that will be used in this investigation

11.1.2 Fixed Laboratory Analytical Method/SOP Modifications

58

CITY_DEP_WORBY_CANNATA_SUBP_000070992

NYC-WTC_000423942

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423942Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →