NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
The cited methods will be followed as written with the exceptions summarized below.
These modifications do not adversely affect the quality or usability of the data as
sufficient quality control analyses will be performed demonstrating adequate method
performance with these modifications.
11.1.2.1 PAPI Extraction by EPA Method TO-13A and Analy.^is by SW-846 Method
8270C
The analysis of PAHs using SW-846 Method 8270C will be modified to include the use
of selective ion monitoring (SIM). Modifications to the sample preparation procedure in
EPA Method TO-13 are listed below.
• The XAD-2 resin is dried in a fume hood for 16 hours instead of dried in a
vacuum oven with ultra-pure nitrogen for 2-4 hours.
• The laboratory uses methylene chloride-rinsed aluminum foil instead of hexane-
rinsed aluminum foil.
• The laboratory uses methylene chloride for the extraction solvent instead of
10% ether/hexane and therefore does not perform the precleaning extraction of
800 mL methylene chloride of the Soxhlet apparatus.
• The final extract is brought down to a volume of 0.5 mL in methylene chloride.
11.1.2.2 Dioxin Extraction by EPA Method T0-9A
• The laboratory uses toluene for the extraction solvent instead of 10% diethyl
cthcr/hcxanc.
59
CITY_DEP_WORBY_CANNATA_SUBP_000070993
NYC-WTC_000423943
OCR can misread numbers and units. Confirm readings against the page image before using them.