Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
10.3 Field Quality Control
This section of the QAPP identifies the QC procedures, checks, samples, and their
respective acceptance limits, that will be used to monitor the quality of various aspects of
the sampling event. Their required analysis frequency, acceptance limits and corrective
actions are also documented in this section of the QAPP.
10.3.1 Field Blanks/Trip Blanks
Field/trip blanks consist of clean sample media. Field/trip blanks accompany samples to
the site and return to the laboratory in the same cooler or shipping container. Field/trip
blanks will be used to ensure that there is no contamination as a result of the
shipment/transportation/on-site storage activities. Field/trip blanks will be collected for
all parameters associated with air samples. Field/trip blanks for asbestos and silica will
only be analyzed if the asbestos or silica are detected in the associated samples.
10.3.2 Cooler Temperature Blanks
Cooler temperature blanks consist of a sample container filled with non-preserved water
(potable or distilled) and are included in all coolers which contain samples which require
temperature preseiwation (PAHs, PCBs, PCDDs/PCDFs). The laboratory uses these
temperature blanks to ensure that proper preservation of the samples has been maintained
during sample shipment. The temperature of these blanks must be 4 °C +2° to
demonstrate that proper preservation has been maintained. The laboratory records the
results of the temperature blanks on the chain-of custody or sample login form
immediately upon receipt of the samples at the laboratory, prior to inventory and
refrigeration.
10.3.3 Field Duplicates
Field duplicates will be collocated samples. Collocated samples are two samples
collected next to each other in the same vertical position. Collocated samples require two
separate sample collections at the same location. Field duplicates will be used to assess
the sampling and analytical reproducibility. With the exception of total mercury, field
duplicates will be submitted at a frequency of once per week per analytical parameter.
For total mercury, field duplicates and field spikes will be alternated on a weekly basis.
Field duplicates for waste characterization will be duplicate subsamples. Duplicate
subsamples are an additional aliquot of the same sample submitted for the same
parameters as the original sample and will be used for aqueous and solid matrices.
Duplicate subsamples will be collected by alternately filling sample containers from the
source being sampled. Field duplicates will be used to assess the sampling and analytical
reproducibility. Field duplicates will be submitted at a frequency of once per 10 samples
70