Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
11.1.2 Fixed Laboratory Analytical Method/SOP Modifications
The cited methods will be followed as written with the exceptions summarized below.
These modifications do not adversely affect the quality or usability of the data as
sufficient quality control analyses will be performed demonstrating adequate method
performance with these modifications.
11.1.2.1 PAH Extraction by EPA Method TO-13A and Analysis by SW-846 Method
8270C
The analysis of PAHs using SW-846 Method 8270C will be modified to include the use
of selective ion monitoring (SIM). Modifications to the sample preparation procedure in
EPA Method TO-13 are listed below.
• The XAD-2 resin is dried in a fume hood for 16 hours instead of dried in a
vacuum oven with ultra-pure nitrogen for 2-4 hours.
• The laboratory uses methylene chloride-rinsed aluminum foil instead of hexane-
rinsed aluminum foil.
• The laboratory uses methylene chloride for the extraction solvent instead of
10% ether/hexane and therefore does not perform the precleaning extraction of
800 mL methylene chloride of the Soxhlet apparatus.
• The final extract is brought down to a volume of 0.5 mL in methylene chloride.
11.1.2.2 Dioxin Extraction by EPA Method T0-9A
• The laboratoiy uses toluene for the extraction solvent instead of 10% diethyl
ether/hexane.