NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
1311 Method 8270C;
4. TCLP pesticide and herbicide toxic constituents. Method SW846-1311
8081Aand8151A.
Building components would generally not be considered as possible RCRA characteristic
wastes except for the potential that exists due to impacts by WTC dust. The notable
exception to this would be surfaces painted with lead-based paint, which would typically
be sampled for TCLP lead analysis. The results of RCRA characteristic analyses, as well
as the material’s status as asbestos contaminated, will be used as the basis for the Waste
Profile for the particular waste stream. All RCRA Characteristic results will be compared
to 40 CFR 261 parts 21 through 23. In addition, the cyanide and sulfide reactivity results
will be compared to SW 846 Chapter 7, Characteristics Introduction and Regulatory
Definitions Interim Guidance Values.
The field personnel will notify the laboratory 24 to 48 hours in advance of sample
shipment so that the laboratory personnel may get prepared for the sample receipt and
analysis. Samples will be packed and shipped in accordance with applicable U.S.
Department of Transportation (DOT) regulations, Environmental Consultant Corporate
Guidelines, and International Air Transport Association (IATA) standards (if shipped by
air carrier, as detailed in the most current edition of IATA Dangerous Goods Regulations
for hazardous materials shipments). Samples will be prepared and shipped to the
laboratory according to the following procedures:
1. All sample jars, once cleaned and labeled, will be placed in clean plastic re-
sealable bags. Medium or high concentration samples (determined through field
obserx^ations, field screening, air monitoring, or all three) will also be packaged in
metal cans. The lids of the metal cans will be secured with at least three metal lid
clips. The exterior of the metal cans will be labeled in the same fashion as the
sample jar.
2. Place samples in a cooler and surround them with vermiculite (or equivalent)
packing material for moisture absorption and stability during transport.
3. Place sufficient double-bagged ice in the cooler to maintain 4°C temperature.
4. Place a "temperature blank", consisting of a water-filled plastic container, in each
cooler. The temperature blank will be recorded by the laboratory upon receipt to
ensure adequate sample temperature.
5. Place completed COG form inside a re-sealable plastic bag, and tape the bag to
the inside of the cooler lid.
6. Secure the cooler lid with packing tape. Place signed and dated custody seals on
two opposite sides of the lid and secure with clear tape.
7. If applicable, tape the drain plug closed so that it will not open.
8. Place upward-pointing arrow label on two opposing vertical sides of the cooler.
9. Label the cooler with laboratory address, name of laboratory contact, telephone
number, and project identification.
10. Attach applicable IATA and/or DOT identification labels.
11. Attach a completed courier shipping label (if applicable).