Samples will be classified as environmental samples unless there is evidence of high
concentrations of chemical constituents, based on visual observations, odors, previous
sample data, or other criteria. All waste liquid, waste solid, tank, drum, and other
container samples will be considered hazardous material samples and will be packaged
and transported in conformance with the U.S. DOT, U.S. Postal Service (USPS), and the
IATA Dangerous Goods Regulations if shipped by air carrier. These
regulations/requirements have de minimus exemptions for small volume samples; they
will be referred to prior sample shipment to ensure all requirements are being met.
The United States Environmental Protection Agency’s Environmental Response Team
(EPA ERT) publishes sampling SOPs for sampling at CERCEA hazardous waste sites.
These SOPs will be followed during the sampling at this site.
QA/QC samples will be collected to assist in the interpretation and validation of the
laboratory analytical results. The QA/QC samples that will be collected during this
characterization sampling program include field duplicates or co-located samples (10
percent of samples). Eield duplicate samples will be collected as a check on laboratory
accuracy and precision. One duplicate dust sample will be collected from the bulk dust
and or high-efficiency particulate air (HEPA) filters. The duplicate sample will be placed
in the appropriate, clean, laboratory-prepared sample containers and analyzed for the
same parameters.
Precision for laboratory and field measurements will be expressed as the relative percent
difference between two duplicate determinations. Acceptance criteria for laboratory
precision will be those specified in the method or +/- 20 percent if not otherwise stated
Data validation will be carried out upon receipt of all laboratory documents. Sample results will
be evaluated to assess potential usability issues. The reported results of all QC checks and
analytical procedures will evaluated, including holding times, sample preservation techniques,
QC sample results, etc. QC samples reviewed to identify potential problems in any of three
specific areas: laboratory/instrument performance, sample preparation/matrix effects, and field
performance. Laboratory and instrument performance will evaluated by reviewing laboratory
blank contamination and instrument calibration data provided by the laboratory. Any unusual
matrix effects will be detected by examining the results from matrix spike/matrix spike
duplicates, surrogate spike recoveries, and internal standard responses as reported by the
laboratory.
Potential problems originating from field sampling work will be
evaluated by examining the field duplicate, equipment blank, and trip blank results.
If the evaluation of QC checks indicate laboratory or field problems, then their impact on the data
will be reported with the sample results.
Before reporting results, raw data will be reviewed in detail to verify the accuracy of the results
reported by the laboratory.