CoC: Environmental Community Air Monitoring Plan

Machine-extracted title · confidence 52%

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

NYC-WTC_000424476–000424609
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - February 1, 2006

1311 Method 8270C; 4. TCLP pesticide and herbicide toxic constituents. Method SW846-1311 8081Aand8151A.

Building components would generally not be considered as possible RCRA characteristic wastes except for the potential that exists due to impacts by WTC dust. The notable exception to this would be surfaces painted with lead-based paint, which would typically be sampled for TCLP lead analysis. The results of RCRA characteristic analyses, as well as the material’s status as asbestos contaminated, will be used as the basis for the Waste Profile for the particular waste stream. All RCRA Characteristic results will be compared to 40 CFR 261 parts 21 through 23. In addition, the cyanide and sulfide reactivity results will be compared to SW 846 Chapter 7, Characteristics Introduction and Regulatory Definitions Interim Guidance Values.

The field personnel will notify the laboratory 24 to 48 hours in advance of sample shipment so that the laboratory personnel may get prepared for the sample receipt and analysis. Samples will be packed and shipped in accordance with applicable U.S. Department of Transportation (DOT) regulations, Environmental Consultant Corporate Guidelines, and International Air Transport Association (IATA) standards (if shipped by air carrier, as detailed in the most current edition of IATA Dangerous Goods Regulations for hazardous materials shipments). Samples will be prepared and shipped to the laboratory according to the following procedures:

1. All sample jars, once cleaned and labeled, will be placed in clean plastic re- sealable bags. Medium or high concentration samples (determined through field observations, field screening, air monitoring, or all three) will also be packaged in metal cans. The lids of the metal cans will be secured with at least three metal lid clips. The exterior of the metal cans will be labeled in the same fashion as the sample jar. 2. Place samples in a cooler and surround them with vermiculite (or equivalent) packing material for moisture absorption and stability during transport. 3. Place sufficient double-bagged ice in the cooler to maintain 4°C temperature. 4. Place a "temperature blank", consisting of a water-filled plastic container, in each cooler. The temperature blank will be recorded by the laboratory upon receipt to ensure adequate sample temperature. 5. Place completed COG form inside a re-sealable plastic bag, and tape the bag to the inside of the cooler lid. 6. Secure the cooler lid with packing tape. Place signed and dated custody seals on two opposite sides of the lid and secure with clear tape. 7. If applicable, tape the drain plug closed so that it will not open. 8. Place upward-pointing arrow label on two opposing vertical sides of the cooler. 9. Label the cooler with laboratory address, name of laboratory contact, telephone number, and project identification. 10. Attach applicable IATA and/or DOT identification labels. 11. Attach a completed courier shipping label (if applicable).

67

CITY_DEP_WORBY_CANNATA_SUBP_000073050

NYC-WTC_000424542

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424542Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427415

CoC document detailing plan for Environmental Community Air Monitoring at Greenwich Street sites.

Similar indexed content

NYC-WTC_000425068

Title and approval sheet for Environmental Community Air Monitoring Program and plan at Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000426957

Plan for environmental community air monitoring at 133-135 Greenwich & 21-23 Thames, Sept 2005.

Similar indexed content

NYC-WTC_000426688

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

Compare copies and versions →