Volume Sampler Calibrator - Capable of providing multipoint resistance for the
highvolume sampler.
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the
internal diameter of the cartridge.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will
insert the PUF plug into the glass sample cartridge during pre-sampling
preparation. • Sample Cartridge Aluminum Shipping Containers - The analytical
laboratory will provide individually labeled containers that will be used to
transport the sample cartridges to the field location and back to the laboratory for
analysis.
• 0-100” Magnehelic Gage.
White Cotton Gloves - For handling the filters and cartridges, and ice chests to
hold samples at 43C during shipment to the analytical laboratory.
10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)
PAH samples will be collected using high-volume air samplers fitted with non-size
selective quartz fiber filters and sorbent cartridges. This approach, as described in EPA
Method TO-13A, does not collect particulate matter representative solely of potential
inhalation exposure, but provides for a total of respirable and non-respirable PAHs.
Sorbent traps containing polyurethane foam (PUF) and XAD-2® resin in a “sandwich”
configuration. The Tisch PUF high volume sorbent sampler (or performance equivalent)
located at each monitoring station will be operated at a flow rate of 200 to 300 liters per
minute with a sampling period of approximately 24 hours for a resulting total air volume
of approximately 288 ms - 432 ms. The filters and sorbent cartridges will be solvent pre
cleaned and vacuum dried by the analytical laboratory. The pre-cleaned filters and
cartridges will be stored wrapped in aluminum foil (or otherwise protected from light) in
a Ziploc bag, and over wrapped with bubble wrap until they are carefully installed on the
sampler on site. At the conclusion of each sampling period, the sample is recovered from
the sampling train by placing the filter inside the glass cartridge. The cartridge is then
wrapped with aluminum foil and it is placed back into its original shipping container,
labeled, and transported to the analytical laboratory for processing. The amount of air
sampled through the filters and cartridges will be recorded and the filter/cartridge set
placed in an appropriately labeled container and shipped to the laboratory
for analysis. Equipment and supplies utilized with this sampling approach are as follows:
• High-Volume Sampler - Tisch PUF (or performance equivalent). Capable of
pulling ambient air through the filter/sorbent cartridge at a flow rate
of approximately 200-300 1pm over a 24-hour sampling period.
• Sampling Module - Metal filter holder capable of holding a 102-mm circular
particle filter supported by a 16-mesh stainless-steel screen and attaching to a
metal cylinder capable of holding a 65-mm O.D. (60-mm I.D.) x 125-mm
borosilicate glass sorbent cartridge containing PUF and XAD-2® resin in the