Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
• High Flow Rotometer - 2.0 to 20.0 Ipm
10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)
PAH samples will be collected using high-volume air samplers fitted with non-size
selective quartz fiber filters and sorbent cartridges. This approach, as described in EPA
Method TO-13 A, does not collect particu late matter representative solely of potential
inhalation exposure, but provides for a total of respirable and non-respirable PAHs.
Sorbent traps containing polyurethane foam (PUF) and XAD-2® resin in a “sandwich”
configuration. The General Metals Works (GMW) PS-1 high volume sorbent sampler (or
performance equivalent) located at each monitoring station will be operated at a flow rate
of 200 to 300 liters per minute with a sampling period of approximately 24 hours for a
resulting total air volume of approximately 288 mi - 432 mi. The filters and sorbent
cartridges will be solvent pre-cleaned and vacuum dried by the analytical laboratory. The
pre-cleaned filters and cartridges will be stored wrapped in aluminum foil (or otherwise
protected from light) in a Ziploc bag, and over wrapped with bubble wrap until they are
carefully installed on the sampler on site. At the conclusion of each sampling period, the
sample is recovered from the sampling train by placing the filter inside the glass
cartridge. The cartridge is then wrapped with aluminum foil and it is placed back into its
original shipping container, labeled, and transported to the analytical laboratory for
processing. The amount of air sampled through the filters and cartridges will be recorded
and the filter/cartridge set placed in an appropriately labeled container and shipped to the
laboratory for analysis. Equipment and supplies utilized with this sampling approach are
as follows:
• High-Volume Sampler - General Metals Works model PS-1 (or performance
equivalent). Capable of pulling ambient air through the filter/sorbent cartridge at a
flow rate of approximately 200-300 1pm over a 24-hour sampling period.
• Sampling Module - Metal filter holder capable of holding a 102-mm circular
particle filter supported by a 16-mesh stainless-steel screen and attaching to a
metal cylinder capable of holding a 65-mm O.D. (60-mm I.D.) x 125-mm
borosilicate glass sorbent cartridge containing PUF and XAD-2® resin in the
“sandwich” configuration. To ensure air-tight seals, the filter holder is equipped
with inert sealing gaskets placed on either side of the filter and inert pliable
gaskets placed at either end of the glass sorbent cartridge.
• High-Volume Sampler Calibrator - Capable of providing multi-point resistance
for the high volume sampler.
• Quartz Fiber Filter - 102 mm binderless quartz microfiber filter. (Provided by
the laboratory, pre-cleaned and weighed.)
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal
diameter of the cartridge.
• XAD-2® Resin - Used to assemble the PUF/XAD-2 “sandwich” cartridges.
Supelco (or equivalent). Pre-cleaned and assembled by the analytical laboratory.
• White Cotton Gloves - For handling the filters and cartridges.