NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
Most of the off-sitc activities described in this QAPP constitute routine sampling and
analyses for which no special training requirements or certifications are needed.
However, all AIRTEK staff working on-site will comply with the 133-135 Greenwich
Street and 21-23 Thames Street Health and Safety Plan in effect at the time. All health
and safety training records are maintained in the AIRTEK files. Prior to the start of the
on-site work, all field personnel will be given instruction specific to the project, covering
the following areas:
• Organization and lines of communication and authority,
• Overview^ of the QAPP, including sample collection, handling, and labeling
procedures,
• QA/QC requirements,
• Documentation requirements, and
• Health and safety requirements. Instructions will be provided by the AIRTEK
Eield Sampling Coordinator and AIRTEK Project QA Officer.
6.0 PROBLEM DEFINITION/BACKGROUND
This section documents project planning, identifies the environmental problem, defines
the environmental questions that need to be answered, and provides background
information.
6.1 Problem Definition/Site History and Background The Buildings at 133-135
Greenwich Street and 21 -23 Thames Street
The events of September 11, 2001, which caused the destruction of the WTC Towers
generated massive debris and dust. While not physically damaged, some of this WTC
dust entered into the 133-135 Greenwich/21-23 Thames Street Buildings. The Buildings
had been partially reoccupied after September 11, 2001 following clearance of debris and
unspecified cleaning to permit re-occupancy.
Eny/ronments/ O/isrscter/zst/on
The Owner contracted with Airtek Environmental Corporation to conduct Asbestos
Surveys and General Building Characterization for the 133-135 Greenwich/21-23
Thames Street buildings. Due to the proximity of these buildings to the WTC, and the
extensive environmental tests carried out at the adjacent 130 Liberty Street (Deutsche
Bank) Building, it is assumed that similar potentially contaminated WTC dust is present
at this site. The settled dust in and on the Building may contain elevated levels of five
COPCs designated by the United States Environmental Protection Agency (USEPA) as
being associated with the WTC dust (asbestos, dioxin, lead, polycyclic aromatic
hydrocarbons [PAHs], and crystalline silica) as well as other contaminants suspected of
being present in the Buildings including polychlorinated biphenyls (PCBs) and heavy
metals (antimony, barium, beryllium, cadmium, chromium, copper, manganese, mercury,
nickel and zinc).
17
CITY_DEP_WORBY_CANNATA_SUBP_000072557
NYC-WTC_000424339
OCR can misread numbers and units. Confirm readings against the page image before using them.