Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Most of the off-sitc activities described in this QAPP constitute routine sampling and analyses for which no special training requirements or certifications are needed. However, all AIRTEK staff working on-site will comply with the 133-135 Greenwich Street and 21-23 Thames Street Health and Safety Plan in effect at the time. All health and safety training records are maintained in the AIRTEK files. Prior to the start of the on-site work, all field personnel will be given instruction specific to the project, covering the following areas:

• Organization and lines of communication and authority, • Overview^ of the QAPP, including sample collection, handling, and labeling procedures, • QA/QC requirements, • Documentation requirements, and • Health and safety requirements. Instructions will be provided by the AIRTEK Eield Sampling Coordinator and AIRTEK Project QA Officer.

6.0 PROBLEM DEFINITION/BACKGROUND

This section documents project planning, identifies the environmental problem, defines the environmental questions that need to be answered, and provides background information.

6.1 Problem Definition/Site History and Background The Buildings at 133-135 Greenwich Street and 21 -23 Thames Street

The events of September 11, 2001, which caused the destruction of the WTC Towers generated massive debris and dust. While not physically damaged, some of this WTC dust entered into the 133-135 Greenwich/21-23 Thames Street Buildings. The Buildings had been partially reoccupied after September 11, 2001 following clearance of debris and unspecified cleaning to permit re-occupancy.

Eny/ronments/ O/isrscter/zst/on

The Owner contracted with Airtek Environmental Corporation to conduct Asbestos Surveys and General Building Characterization for the 133-135 Greenwich/21-23 Thames Street buildings. Due to the proximity of these buildings to the WTC, and the extensive environmental tests carried out at the adjacent 130 Liberty Street (Deutsche Bank) Building, it is assumed that similar potentially contaminated WTC dust is present at this site. The settled dust in and on the Building may contain elevated levels of five COPCs designated by the United States Environmental Protection Agency (USEPA) as being associated with the WTC dust (asbestos, dioxin, lead, polycyclic aromatic hydrocarbons [PAHs], and crystalline silica) as well as other contaminants suspected of being present in the Buildings including polychlorinated biphenyls (PCBs) and heavy metals (antimony, barium, beryllium, cadmium, chromium, copper, manganese, mercury, nickel and zinc).

17

CITY_DEP_WORBY_CANNATA_SUBP_0001 01048

NYC-WTC_000427732

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427732Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →