NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - February 1, 2006
recovered from the sampling train by placing the filter inside the glass cartridge. The
glass cartridge is then wrapped with aluminum foil and it is placed back into its original
shipping container, labeled, and transported to the analytical laboratory for
processing. Equipment and supplies utilized with this sampling approach are as follows:
• High-Volume Sampler - Tisch PUF (or equivalent), capable of pulling ambient
air through the filter/adsorbent cartridge sampling train at a flow rate of 200- 300
1pm to obtain a total sample volume of 288-432 ms over a 24-hour period. • High-
Volume Sampler Calibrator - Capable of providing multipoint resistance for the
highvolume sampler.
• Quartz Fiber Filters - 102 millimeter (102-mm) bindless quartz microfiber filter,
Whatman International Ltd, QMA-4 (or equivalent), provided by the laboratory,
pre-cleaned and weighed.
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the
internal diameter of the cartridge.
• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate
seal to prevent pre- or post- sampling exposure to other potential sources of the
target analytes.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will
insert the PUF plug into the glass sample cartridge during pre-sampling
preparation. • Sample Cartridge Aluminum Shipping Containers - The analytical
laboratory will provide individually labeled containers that will be used to
transport the sample cartridges to the field location and back to the laboratory for
analysis.
• 0-100” Magnehelic Gage.
• White Cotton Gloves - For handling the filters and cartridges.
• Ice Chests - To hold samples at 4T' during shipment to the analytical laboratory.
10.2.6 Polychlorinated Biphenyls (PCBs)
Ambient air samples will be collected using a Tisch PUF (or performance equivalent)
high volume air sampling system equipped for the collection of air through a glass
cylinder containing a polyurethane sorbent (i.e., PUF plug) for the collection of organic
vapors. At each site, one Tisch PUF sampler will be used to collect PCB samples
according to Method TO-4A. Samples will be collected at a flow rate of 200 to 300 liters
per minute (1pm) over a sampling period of approximately 24 hours for a resulting total
air volume of approximately 288-432 cubic meters (288-432 ms). For each sample, the
sampling start and end times and flow rates are recorded on Field Sampling Data Sheets
and in the site calibration logbook and used to calculate the amount of ambient
air sampled. At the conclusion of each sampling period. Equipment and supplies utilized
with this sampling approach are as follows:
• High-Volume Sampler - Tisch PUF (or equivalent), capable of pulling ambient
air through the filter/adsorbent cartridge sampling train at a flow rate of 200- 300
1pm to obtain a total sample volume of 288-432 ms over a 24-hour period. • High-
62
CITY_21MC100_0 03239915
NYC-WTC_000446683
OCR can misread numbers and units. Confirm readings against the page image before using them.