Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - February 1, 2006

Volume Sampler Calibrator - Capable of providing multipoint resistance for the highvolume sampler. • Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type (density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal diameter of the cartridge. • Glass Sample Cartridge - For sample collection. The analytical laboratory will insert the PUF plug into the glass sample cartridge during pre-sampling preparation. • Sample Cartridge Aluminum Shipping Containers - The analytical laboratory will provide individually labeled containers that will be used to transport the sample cartridges to the field location and back to the laboratory for analysis. • 0-100” Magnehelic Gage. White Cotton Gloves - For handling the filters and cartridges, and ice chests to hold samples at 4%! during shipment to the analytical laboratory.

10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)

PAH samples will be collected using high-volume air samplers fitted with non-size selective quartz fiber filters and sorbent cartridges. This approach, as described in EPA Method TO-13A, does not collect particulate matter representative solely of potential inhalation exposure, but provides for a total of respirable and non-respirable PAHs. Sorbent traps containing polyurethane foam (PUF) and XAD-2® resin in a “sandwich” configuration. The Tisch PUF high volume sorbent sampler (or performance equivalent) located at each monitoring station will be operated at a flow rate of 200 to 300 liters per minute with a sampling period of approximately 24 hours for a resulting total air volume of approximately 288 ma - 432 ma. The filters and sorbent cartridges will be solvent pre­ cleaned and vacuum dried by the analytical laboratory. The pre-cleaned filters and cartridges will be stored wrapped in aluminum foil (or otherwise protected from light) in a Ziploc bag, and over wrapped with bubble wrap until they are carefully installed on the sampler on site. At the conclusion of each sampling period, the sample is recovered from the sampling train by placing the filter inside the glass cartridge. The cartridge is then wrapped with aluminum foil and it is placed back into its original shipping container, labeled, and transported to the analytical laboratory for processing. The amount of air sampled through the filters and cartridges will be recorded and the filter/cartridge set placed in an appropriately labeled container and shipped to the laboratory for analysis. Equipment and supplies utilized with this sampling approach are as follows:

• High-Volume Sampler - Tisch PUF (or performance equivalent). Capable of pulling ambient air through the filter/sorbent cartridge at a flow rate of approximately 200-300 1pm over a 24-hour sampling period. • Sampling Module - Metal filter holder capable of holding a 102-mm circular particle filter supported by a 16-mesh stainless-steel screen and attaching to a metal cylinder capable of holding a 65-mm O.D. (60-mm ED.) x 125-mm borosilicate glass sorbent cartridge containing PUF and XAD-2® resin in the

63

CITY_DEP_WORBY_CANNATA_SUBP_000073046

NYC-WTC_000424538

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424538Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427415

CoC document detailing plan for Environmental Community Air Monitoring at Greenwich Street sites.

Similar indexed content

NYC-WTC_000425068

Title and approval sheet for Environmental Community Air Monitoring Program and plan at Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000426957

Plan for environmental community air monitoring at 133-135 Greenwich & 21-23 Thames, Sept 2005.

Similar indexed content

NYC-WTC_000426688

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

Compare copies and versions →