In light of the recent concerns expressed regarding contaminants in the homes
cleaned during the Lower Manhattan Residential Cleanup Program [LMRCP], I feel
it would be extremely useful for the panel to see the range of exposure found by
USDOL/OSHA at the WTC site during recovery efforts, and in actual homes during
cleaning. It is important to note that the majority of these tests were taken (for the
most part) on workers who were actively disturbing debris and represent worst-case
scenarios. OSHA compliance officers took over 6,500 individual samples at the
WTC Recovery Site representing 81 different analytes, and performed more than
24,000 analyses on these samples. Most of those samples were worker breathing zone
samples and were analyzed for multiple substances. These samples showed exposures
well below the Agency's Permissible Exposure Levels for the majority of chemicals
and substances analyzed.
During the LMRCP, OSHA chose to sample for four substances identified in
September 2002 as contaminants of potential concern [COPC] by the COPC
Committee of the World Trade Center Indoor Air Taskforce Working Group. That
committee included EPA, FEMA, NY City Department of Environmental Protection,
NY City Department of Health and Mental Hygiene, ATSDR, NY State Department
of Health, and USDOL/OSHA. The contaminants chosen by the group were asbestos,
lead, fibrous glass and respirable crystalline silica. Analyses for total fibers were
also conducted on the asbestos/fibrous glass samples and analyses for total dust was
conducted on select metals samples.
All samples [287] in the LMRCP were non-detected for asbestos using Phase
Contrast Microscopy [PCM]. During the WTC Recovery project, 1425 samples were
taken for airborne asbestos, 179 samples exceeded OSHA's limit via PCM analysis.
Upon further analysis using discriminating counting methods and/or TEM analysis,
the number of asbestos fibers found dropped dramatically below detectable levels or
well below 0.1 fiber/cc. Additionally, more than 95% of these samples were found to
be below detection limits.
Although lead levels were of public concern at the hearings, no detectable amounts
were found in the air while cleaning the residences. Fourteen of the 61 wipe samples,
taken before cleaning began, were positive for lead. Results ranged from 0.0062
mg/100cm2 to 0.070 mg/100cm2. The high ranges were referred to the NYC
Department of Health and Mental Hygiene. Lead exposure was found at the WTC
site; however, in most cases workers were burning through lead paint or lead
sheathing on the Tower 1 Mast. 1331 metal sample were taken at the WTC site and
analyzed for a variety of metals, and only approximately 5.2 % revealed exposures
that exceeded their respective metal PELs (personal and area samples in total).
It is noteworthy that very little heavy metals levels were found at the WTC recovery
site. This is particularly true for mercury. No mercury was detected in the 242 air
samples taken in and around the WTC pit. In 36 bulk samples taken between 10/3/01
and 12/16/01, mercury was not detected. Ten bulks were taken on 1/3/02, 9 in the pit
were reported as no mercury detected, 1 sample near WTC 6 found 0.9 ppm. Fifty-
CITY_21MC100_003218366
NYC-WTC_000446130
OCR can misread numbers and units. Confirm readings against the page image before using them.