NYC 9/11 Public Portal Document
Draft May 10, 2004
two bulks taken between 1/8/02 and 1/11/02 ranged in results between 0.1 to 0.2 ppm,
which is consistent with background levels for New York City. Mercury was not
investigated during the Lower Manhattan Residential Cleanup Program, since it was
not found to be a significant constituent of the WTC debris.
Although fibrous glass was detected in four of the 287 air samples for fibers in the
LMRCP, all indicated exposure to significantly less than 1 fiber per cubic centimeter
of air. Glass fiber exposures ranged from 0.0032 to 0.22 f/cm3, well below the
published exposure limit for this substance. OSHA used the more protective
exposure limit of 1 f/cm3 for comparison purposes, recommended by the American
Conference of Governmental Industrial Hygienists, rather than the agency's limit of
15 mg/m3. A more complete discussion can be found in the attached summary on the
cleaning program.
None of the 75 air samples taken in the LMRCP for crystalline silica exceeded the
permissible exposure limit [PEL]. Respirable crystalline silica was detected in 61
of the 75 samples. At the WTC site operations the overwhelming majority of 1353
silica samples taken showed no detectable levels of airborne silica. However, 94
samples did exceed the PEL. These were all during heavy dust producing jobs, such
as jack hammering concrete, slurry wall drilling, and chipping concrete with power
tools, etc and they are only indicative of the exposure to the individual being
sampled.
To summarize, even in the WTC recovery site heavy debris removal operations there
was not an overwhelming number of overexposures. In the clean-up phase of Lower
Manhattan (LMRCP), overexposures were not found. This information should be
helpful to you in determining what resources will be used to determine the levels of
contamination possibly still present in the residences.
A summary document of the LMRCP is attached. Results for sampling at both the
World Trade Center Site and the LMRCP can also be found at:
■ <http://www.osha.gov/nyc-disaster/wtc.html>
■■■ <http://www.osha.gov/nyc-disaster/wtc-final-residential-dust-cleanup-
program.pdf>
CITY_21MC100_003218367
NYC-WTC_000446131
OCR can misread numbers and units. Confirm readings against the page image before using them.