NYC 9/11 Public Portal Document
New York State Department of Labor
Division of Safety and Health
Sampling Summary as of 2/13/2002
Personal exposure sampling has been performed on numerous employees working on and
around the WTC site. This has included firefighters, police officers, state troopers, corrections
officers, police detectives, and sanitation workers. The New York State Department of Labor has
to date collected over 260 personal exposure samples on public employees working at the site
with over 2200 analyses performed. The sampling summary below is for activity up to
1/30/2002.
Asbestos Over 45 personal samples have been collected so far with results ranging
from not detectable to 0.116 fibers per cc by PCM analysis. The use of TEM on 2
samples which initially were above the PEL of 0.1 fibers per cc resulted in a
reduction to at least 0.016 fibers per cc. Most results by PCM analysis have been
well below the PEL of 0.1 fibers /cc.
Bulk samples were collected in FDNY vehicles during the month of
January to assist the department with an evaluation of contamination. All
of these samples had results which were below the detection limit.
Carbon Monoxide Results for 44 personal exposure samples ranged from 0 to 4 ppm as a
time weighted average, well below the PESH PEL of 35 ppm. Peak measurements
reached 97 ppm on a personal monitor, still well below the ceiling limit of 200 ppm.
Silica Personal sampling (17 samples) results have shown most exposures to be
below the detection limit for respirable silica with all exposures well
below the PESH PEE of 0.1 mg/m3
Metals Personal samples (37) collected show all exposures to be below the PESH
PELs. Metals analyzed included lead, copper, manganese, molybdenum,
magnesium, cadmium, nickel, iron, aluminum, zinc, and cobalt.
Surface wipe samples in some of the FDNY’s response vehicles were
taken to assist the department with an evaluation of contamination of
vehicles which had responded to the WTC site during the first few days of
the disaster. These results are included in the data spreadsheet.
Volatile organics All personal sampling results have been well below PESH limits for 32
screening samples collected for volatile organics. These samples included analyses for
the following: acetone, benzene, ethyl benzene, butyl alcohol, isopropyl alcohol, naphtha,
styrene, toluene, and xylene.
Acid gases Exposures to acid gases such as hydrogen bromide, hydrogen chloride,
hydrogen cyanide, and hydrogen fluoride were all below the detection limit. For
CITY_21MC100_003211432
NYC-WTC_000441789
OCR can misread numbers and units. Confirm readings against the page image before using them.