OSHA WTC sampling results summary

Machine-extracted title · confidence 33%

OSHA sampling results overview for asbestos and related exposure at WTC site.

NYC-WTC_000246073–000246074
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OSHA WTC Sampling Results

Polynuclear Aromatic Hydrocarbons

OSHA has taken 110 samples (excluding blanks). The majority of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified eight samples which reached or exceeded OSHA's coal tar pitch volatile PEL of 0.2mg/m3 . These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to recommend the use of respiratory protection when working in the debris field.

Freon R-22, Hydrogen Fluoride & Phosgene

OSHA has taken a total of 214 samples for Freon R-22 (chlorodiflouromethane), hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level of 6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other samples were none­ detected. OSHA does not have an exposure limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for the decomposition products of Freon R-22, hydrofluoric acid (HF) and phosgene showed no detectable levels.

Inorganic Acids

OSHA has taken approximately 255 samples for inorganic acids such as hydrochloric, phosphoric, and sulfuric acids. Four samples for sulfuric acid were found to exceed OSHA's permissible exposure limit (PEL) of 1 mg/m^. Workers were sorting debris.

Oxides of Nitrogen/Sulfur

Sampling on grappler operators on the rubble pile, and on employees at the truck wash stations revealed trace levels of nitric oxide and nitrogen dioxide. SO2 personal and area results were found to be below OSHA limits.

Metals

OSHA has taken a total of 1331 samples (excluding bulk and blank samples) to monitor worker exposures to dusts, fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium, cobalt, copper, iron, lead, manganese, mercury, molybdenum, nickel, vanadium, zinc, cadmium, magnesium, and arsenic. To minimize the length of the "WTC OSHA Heavy Metal Monitoring Data tables" only the samples that showed detected results for these metals are listed. Results from these samples are generally well below the applicable OSHA limits. However, torch cutting and burning structural steel at the rubble pile have resulted in instances of overexposures as follows: copper (17); iron oxide (28); lead (19); zinc oxide (1), antimony (1); and cadmium (3). Accordingly, OSHA is recommending that workers engaged in these operations wear appropriate respiratory protection. See information below for the specific counts in regards to mercury.

Mercury

OSHA has taken 242 air samples for inorganic mercury. No mercury was detected. Also, 36 bulk samples previously collected from rubble were re-analyzed for mercury and none was detected. Additionally, 10 bulks were taken on 1/3, with one sample detecting mercury at 0.9ppm and nine samples did not contain mercury. 38 bulk samples were taken between 1/8 and 1/11/02; results indicate 0.1 to 0.2 ppm mostly in around the footprint of Bldg.-6, and in the pit between WTC tower 1&2. 10 bulks taken on 6/5, inside 130 Cedar, detected mercury from 0.3 to 0.5 ppm. One bulk taken in 130 Cedar on the Sth floor in the lab area (off floor below lab table) detected 10.0 ppm mercury.

Ionizing Radiation

A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with particular attention to alpha radiation. Results show no elevated levels of concern from either known building latent radiation sources or any terrorist origin source materials.

Back to Top www.osha.qov www.dol.qoy

Contact Us | Freedom of Information Act | Information Quality | Customer Survey Privacy and Security Statement | Disclaimers

Occupational Safety & Health Administration 200 Constitution Avenue, NW Washington, DC 20210

httn*/AAAAn« immarx? h+ml Z9 r>f 9^ rQ/9ft/9nn9 'in’A’1'9ft

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014660495

NYC-WTC_000246074

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000246074Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

OSHA sampling results summary, January 2002

NYC-WTC_000232887

Summary report detailing OSHA personal air sampling results for asbestos and other hazards in the financial district as of January 16, 2002.

Similar indexed content

Compare copies and versions →