Chemical Reason Mercury Concern regarding mercury has been raised by a report of slightly elevated blood mercury levels in four Port Authority Police Officers at the WTC site (69 were screened). A NYC Department of Design and Construction report [Rottner, 2002] concluded that air and bulk data have not shown elevated Hg levels. The report also noted that routine urine screening of NYC firefighters assigned to the site did not indicate any sign of Hg exposure. A U.S. Geological Survey leachability study [USGS 2001] of indoor and outdoor WTC settled dust samples showed that it is unlikely that harmful levels of mercury could ever be released to the air. Particulate Ambient monitoring in the WTC area has shown that, since late October, levels Matter of PM 10 and PM 2.5 (two commonly measured inhalable PM sizes) have been (PM) below EPA’s level of concern for the ambient air (see Appendix B), indicating that there is no continuing source of PM entering homes and offices. EPA’s Environmental Data Trend Report World Trade Center, 9/11/01 - 4/24/02 [EPA, 2002a] concluded that PM 2.5 and PM 10 appear to have returned to levels of a steady background state. Refractory Ceramic fiber-containing materials are not expected to be present in the WTC Ceramic buildings, as they are mainly used in industrial high temperature applications. Fibers Limited sampling conducted by NYCDOH and ATSDR did not indicate any (RCF) ceramic fibers in four indoor air samples analyzed by SEM. Mold Mold was not directly associated with the WTC collapse. However, it may have resulted from the combination of water damage and inoperable HVAC systems. Guidelines for identifying and removing mold are provided through a NYCDOH website (see Appendix A).

Setting Benchmarks for the Contaminants off Potential Concern (COPCs)

A tiered approach was used to evaluate the health risks posed by contaminants that might be present in the indoor environment (air and settled dust). For each COPC, three levels were established:

Tier I Level above which, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), aggressive clean-up action should be taken expeditiously along with follow-up sampling to confirm attainment of Tier HI level Tier n Range where diligent cleaning should continue, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), with follow­ up sampling to confirm attainment of Tier EH level

8

NYC-WTC_000242781

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242781Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →