NYC 9/11 Public Portal Document
Chemical Reason
Mercury Concern regarding mercury has been raised by a report of slightly elevated
blood mercury levels in four Port Authority Police Officers at the WTC site (69
were screened). A NYC Department of Design and Construction report
[Rottner, 2002] concluded that air and bulk data have not shown elevated Hg
levels. The report also noted that routine urine screening of NYC firefighters
assigned to the site did not indicate any sign of Hg exposure. A U.S. Geological
Survey leachability study [USGS 2001] of indoor and outdoor WTC settled dust
samples showed that it is unlikely that harmful levels of mercury could ever be
released to the air.
Particulate Ambient monitoring in the WTC area has shown that, since late October, levels
Matter of PM 10 and PM 2.5 (two commonly measured inhalable PM sizes) have been
(PM) below EPA’s level of concern for the ambient air (see Appendix B), indicating
that there is no continuing source of PM entering homes and offices. EPA’s
Environmental Data Trend Report World Trade Center, 9/11/01 - 4/24/02 [EPA,
2002a] concluded that PM 2.5 and PM 10 appear to have returned to levels of a
steady background state.
Refractory Ceramic fiber-containing materials are not expected to be present in the WTC
Ceramic buildings, as they are mainly used in industrial high temperature applications.
Fibers Limited sampling conducted by NYCDOH and ATSDR did not indicate any
(RCF) ceramic fibers in four indoor air samples analyzed by SEM.
Mold Mold was not directly associated with the WTC collapse. However, it may have
resulted from the combination of water damage and inoperable HVAC systems.
Guidelines for identifying and removing mold are provided through a NYCDOH
website (see Appendix A).
Setting Benchmarks for the Contaminants off Potential Concern (COPCs)
A tiered approach was used to evaluate the health risks posed by contaminants that might be
present in the indoor environment (air and settled dust). For each COPC, three levels were
established:
Tier I Level above which, after elimination of potential indoor sources (combustion
by-products, stored chemicals, etc.), aggressive clean-up action should be
taken expeditiously along with follow-up sampling to confirm attainment of
Tier HI level
Tier n Range where diligent cleaning should continue, after elimination of potential
indoor sources (combustion by-products, stored chemicals, etc.), with follow
up sampling to confirm attainment of Tier EH level
8
NYC-WTC_000242781
OCR can misread numbers and units. Confirm readings against the page image before using them.