NYC 9/11 Public Portal Document
Tier HI Level below which the risk is negligible or consistent with the New York City
background level found in the aforementioned Background Study.
Each level (or "benchmark screening value") was established based on existing environmental
standards, where available and applicable. For example, Tier I screening levels for lead in indoor
air and settled dust were set using EPA’s National Ambient Air Quality Standard (NAAQS) and
the U.S. Housing and Urban Development’s (HUD’s) standard for floors, respectively.
In cases where appropriate standards did not exist, risk-based criteria were developed using
established EPA risk assessment methods: for indoor air, methods described in EPA’s "Risk
Assessment Guidance for Superfund" [RAGS, 1989] were used; for settled dust, EPA Region
ni’s "Wipe Sample Assessment" guidance was used (see Appendix C). The risk-based criteria
reflect the most current toxicity criteria (cancer Slope Factors and RfDs/RfCs) on EPA’s
Integrated Risk Information System (IRIS), which is a regularly updated, online database that
reports chemical toxicity reference values and information on human health effects that may
result from exposure to chemicals in the environment.
Individual sampling results that exceed benchmark values should not be interpreted to represent
the occurrence of an adverse health effect. Because benchmark levels assume continuous
exposure for an extended duration, the average of the measured concentrations is more
appropriate for evaluating risk than individual measurements. Consequently, isolated individual
values above the benchmark level may not necessarily be indicative of a hazard.
Developing Risk-Based Criteria for Indoor Air
For carcinogenic compounds, the benchmarks were set so that a local resident’s lifetime risk of
developing cancer from exposure to WTC-related contaminants would not exceed a one-in-ten-
thousand probability (1x10"*) above the resident’s background risk without this exposure. The
amount of time that residents and office workers were exposed to WTC-related contaminants is
unknown. To be conservative, the Tier I screening level was chosen to be protective of a resident
who may have been exposed to WTC-related contaminants for one year. The Tier in clearance
level was chosen to be protective of a resident who is exposed to WTC-related contaminants for
30 years, which is the upper-bound estimate for residency in one dwelling [EPA, 1989]. The
cancer risk level (1x10 “) employed herein reflects the upper bound of the acceptable risk range
(10'“ to 10 ®) established in EPA’s Superfund regulation [Federal Register, 1990]. Practical
Quantitation Limits (PQLs, the lowest level that can be reliably achieved within specified limits
of precision and accuracy during routine laboratory operating procedures [EPA, 1992]) and
anticipated background levels [ATSDR, 1995] dictated the selection of the risk level at lxl0 “. A
more detailed discussion of this subject can be found in Appendix C.
For non-carcinogenic compounds, airborne contaminant concentration is compared to the
Reference Concentration (RfC). The RfC is an estimate of a chronic exposure concentration for
the human population, including sensitive subpopulations, that is likely to be without an
9
NYC-WTC_000242782
OCR can misread numbers and units. Confirm readings against the page image before using them.