with additional safety factors. Accordingly, a reviev/ of environmental standards/regulations was conducted for each of the six COPCs. As a result of this exercise Tier I screening levels for MB lead in indoor air and settled dust were set using EPA’s N ational Ambient Air Quality Standard (NAAQS) and the U.S. Housing and Urban Development’s (HUD’s) standard for floors, respectively. The clearance criteria established in the Asbestos Hazard Emergency Response Act iMI (AHERA, 1986) of 70 structures/nim2 was utilized to evaluate asbestos samples from the ambient air monitoring effort. As detailed in Appendix B, the upper bound estimate for exposure duration to contaminants in the ambient air was one year. However, given the potential for extended exposure in residential dwellings, AHERyK was deemed less appropriate to this setting.

In cases where appropriate standards did not exist (e.g., asbestos), risk-based criteria were DM developed using established EPA risk assessment methods: for indoor air, methods described in EPA’s “Risk Assessment Guidance for Superfund” [RAG S, 1989] were used; for settled dust, EPA Region Hl’s “Wipe Sample Assessment” guidance was utilized with modifications (see ■H Appendix D). The risk-based criteria reflect the most current toxicity criteria (Cancer Slope Factors and RfDs/RfCs) on EPA’s Integrated Risk Information System (IRIS), which is a regularly updated (quarterly), online database that reports chemical toxicity reference values and .M information on human health effects that may result from exposure to chemicals in the environment.

<W For contaminants that lacked DUS verified toxicity criteria, occupational standards were employed. Additional safety factors were added to account for higher exposure and greater sensitivity within the general population. M The clearance criteria paradigm described above is pathway and chemical specific. Accordingly, the benchmarks for each COPC do not account for multimedia and multiple chemical exposure.

Individual sampling results that exceed benchmark values should not be interpreted to represent the occurrence of an adverse health effect. Because benchmark levels assume continuous M exposure for an extended duration, the average of the measured concentrations is more appropriate for evaluating risk than individual measurements. Consequently, isolated individual values above the benchmark level may not necessarily be indicative of a hazard. Ml Developing Risk-Based Criteria for Indoor Air

For carcinogenic compounds, the benchmarks were set so that a local resident’s lifetime risk of developing cancer from exposure to WTC-related contaminants would not exceed a one-in-ten- thousand probability (1x10”’) above the resident’s background risk without this exposure. The MM amount of time that residents and office workers were exposed to WTC-related contaminants is unknown. To be conservative, the Tier I screening level xvas chosen to be protective of a resident who may have been exposed to WTC-related contaminants for one year. The Tier HI clearance level was chosen to be protective of a resident who is exposed to WTC-related contaminants for 30 years, which is the upper-bound estimate for residency in one dwelling [EPA, 1989]. Cancer

11

Ml

NYC-WTC_000242999

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000242999Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →