NYC 9/11 Public Portal Document
appreciable risk of deleterious effects during a lifetime [EPA, 1989]. That comparison (i.e,
chronic exposure concentration/RfC) is called the Hazard Quotient (HQ). According to EPA
guidelines [EPA, 1989], if the HQ is greater than one, there may be concern for potential health
effects. Therefore, for Tier HI (clearance level), the benchmark screening level was set at an HQ
of 1. For Tier I, which equates to a sub-chronic exposure scenario, an HQ of 10 was used, in
accordance with EPA’s Hazard Evaluation Handbook [EPA, 1997]. An HQ of 10 accounts for
the fact that chronic toxicity criteria (RfDs/RfCs) are being applied to sub-chronic exposure
scenarios (i.e., exposure not expected to exceed 6 months to one year in duration). Accordingly,
an HQ of 10 was used for non-carcinogens to reflect a similar (i.e., upper bound of 1 year)
exposure duration. Note that contaminants (both non-carcinogens and carcinogens, alike) can
exhibit acute effects from short-term, high-dose exposures. Because the Tier I benchmark levels
are based on subchronic exposure (i.e., 1 year), acute effects from exposures that are below the
benchmark levels would be unlikely. A review of EPA’s draft Acute Exposure Guideline Levels
[EPA, 2001a] and California EPA’s (CAL-EPA) Acute Risk Levels demonstrates that the
benchmark levels developed herein are categorically more stringent than the analogous US EPA
and Cal-EPA acute levels.
Developing Risk-Based Criteria for Settled Dust
A full discussion of the methodology employed for developing risk-based benchmarks based on
wipe sampling data is presented in Appendix C. Briefly, this methodology provides an estimate
of daily dose to a contaminant based on interior surface load sampling data. Dose is obtained by
estimating the following: skin contact area and contact frequency with contaminated surfaces,
transfer efficiency between surface and hand, transfer efficiency between hand and mouth, oral
absorption of the contaminant and dermal absorption of residual contamination on skin.
Consistent with the approach for indoor air, toxicity criteria (oral cancer Slope Factors and RfDs)
were obtained from IRIS. This section provides the basis for the values used in the assessment of
wipe sampling data.
There is no established national guidance, and limited scientific literature, for the estimation of
risk from wipe samples. The approach used in this report was developed by the EPA Region HI
Superfund program and has been employed by the U.S. Army Corps of Engineers to develop
risk-based clean-up goals for interior surfaces at the Claremont Polychemical Superfund site in
Region n [Radian, 1999]. Its methodology is similar to an approach employed by the NYSDOH
for evaluating a dioxin contaminated office building [NYSDOH, 1985] and one previously
proposed by NJDEP for setting interior building surface clean-up goals [NJDEP, 1993]. For the
purpose of developing risk-based clearance levels for interior surfaces, this approach is
preferable to an approach that relies on measuring contaminant concentration on a weight per
weight (ppm) basis (as might be done for an exterior soil assessment). After cleaning has
occurred, it would be difficult to obtain the mass of dust necessary to perform a mass per mass
measurement of contaminant concentration. In addition, literature on interior lead contamination
demonstrates a strong correlation between lead load (mass per unit area) and blood lead
concentration in children (Lanphear et. al., 1998).
10
NYC-WTC_000242783
OCR can misread numbers and units. Confirm readings against the page image before using them.