upper bound of 1 year) exposure duration. Note that contaminants (both non-carcinogens and carcinogens, alike) can exhibit acute effects from short-term, high-dose exposures. Because the Tier I benchmark levels are based on subchronic exposure (i.e., 1 year), acute effects from exposures that are below the benchmark levels would be imlikely. A review of EPA’s draft Acute Exposure Guideline Levels [EPA, 2001a] and California EPA’s (CAL-EPA) Acute Risk Levels demonstrates that the benchmark levels developed herein are categorically more stringent than the analogous US EPA and Cal-EPA acute levels.

Developing Risk-Based Criteria for Settled Dust

There is no established national guidance, and limited scientific literature, for assessing risk from interior surface wipe sampling (i.e., mass per unit area) data . The approach used in this report was adapted and modified from a methodology developed by the EPA Region III Superfiind Program. It has been employed by the U.S. Army Corps of Engineers to develop risk-based clean-up goals for interior surfaces at the Claremont Polychemical Superfund site in Region II [Radian, 1999]. Additionally, the methodology is similar to an approach employed by the NYSDOH for evaluating a dioxin contaminated office building [NYSDOH, 1985] and one previously proposed by NJDEP for setting interior building surface clean-up goals [NJDEP, 1993].

A full discussion of the methodology employed for developing risk-based benchmarks based on contact with residues on indoor surfaces is presented in Appendix D. Briefly, this methodology provides an estimate of daily dose resulting from dermal absorption and ingestion associated with contacting contaminated surfaces and hand-to-mouth transfers. Dose is obtained by estimating the following: skin contact area and contact frequency with contaminated surfaces, transfer efficiency between surface and hand, transfer efficiency between hand and mouth, oral absorption of the contaminant and dermal absorption of residual contamination on skin. Consistent with the approach for indoor air, toxicity criteria were obtained from IRIS. The assessment procedure is described briefly below and in more detail in Appendix D.

For the purpose of developing risk-based clearance levels for interior surfaces, this approach is preferable to an approach that relies on measuring contaminant concentration on a mass per mass (ppm) basis (as might be done for an exterior soil assessment). After cleaning has occurred, it would be difficult to obtain the mass of dust necessary to perform a mass per mass measurement of contaminant concentration. In addition, literature on interior lead contamination demonstrates a strong correlation between lead load (mass per unit area) and blood lead concentration in children (Lanphear et. al., 1998).

The following table lists the input parameters and numerical values (along with a brief explanation) used in this procedure. (See Appendix D for equations and a more detailed discussion.)

Table 3. Exposure parameters used to calculate clearance criteria for wipe samples.

14

CITY_21MC100_004053242

NYC-WTC_000320476

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320476Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →