Developing Risk-Based Criteria for Settled Dust

A full discussion of the methodology employed for developing risk-based benchmarks based on wipe sampling data is presented in Appendix C. Briefly, this methodology provides an estimate of daily dose to a contaminant based on interior surface load sampling data. Dose is obtained by estimating the following: skin contact area and contact frequency with contaminated surfaces, transfer efficiency between surface and hand, transfer efficiency between hand and mouth, oral absorption of the contaminant and dermal absorption of residual contamination on skin. Consistent with the approach for indoor air, toxicity criteria (oral cancer Slope Factors and RfDs) were obtained from IRIS. This section provides the basis for the values used in the assessment of wipe sampling data.

There is no established national guidance, and limited scientific literature, for the estimation of risk from wipe samples. The approach used in this report was developed by the EPA Region III Superfund program and has been employed by the U.S. Army Corps of Engineers to develop risk-based clean-up goals for interior surfaces at the Claremont Polychemical Superfund site in Region 11 [Radian, 1999]. Its methodology is similar to an approach employed by the NYSDOH for evaluating a dioxin contaminated office building [NYSDOH, 1985] and one previously proposed by NJDEP for setting interior building surface clean-up goals [NJDEP, 1993]. For the purpose of developing risk-based clearance levels for interior surfaces, this approach is preferable to an approach that relies on measuring contaminant concentration on a weight per weight (ppm) basis (as might be done for an exterior soil assessment). After cleaning has occurred it would be difficult to obtain the mass of dust necessary to perform a mass per mass measurement of contaminant concentration. In addition, literature on interior lead contamination demonstrates a strong correlation between lead load (mass per unit area) and blood lead concentration in children (Lanphear et. al., 1998).

The following table details the input parameters for the derivation of risk-based clearance levels for interior surfaces.

Input Parameter Value Explanation SA (Skin Surface Area - cm^) 400 cm^ See Appendix C CF (Contact Frequency) 16 1/day Best Professional Judgement FTSS (Fraction Transferred from .05 See Appendix C Surface to Skin EF (Exposure Frequency) 350 days/yr Days in Residence [EPA, 1989] ED (Exposure Duration) 30 years Upper-bound Estimate of Time in Residence [EPA, 1989]

8

CITY_21MC100_0 08969680

NYC-WTC_000317663

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317663Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →