NYC 9/11 Public Portal Document
extended duration, the average of the measured concentrations is more appropriate for evaluating
risk than an individual measurements. Consequently, isolated individual values above the
benchmark level may not necessarily be indicative of a hazard.
Developing Risk-Based Criteria for Indoor Air
For carcinogenic compounds, the benchmarks were set so that a local resident’s lifetime risk of
developing cancer from exposure to WTC-related contaminants would not exceed a one-in-ten-
thousand probability above the resident’s background risk without this exposure (in risk
assessment terms, the excess lifetime cancer risk was set at 1 E-04). The amount of time that
residents and office workers were exposed to WTC-related contaminants is unknown. To be
conservative, the Tier I screening level was chosen to be protective of a resident who may have
been exposed to WTC-related contaminants for one year. The Tier III clearance level was
chosen to be protective of a resident who is exposed to WTC-related contaminants for 30 years,
which is the upper-bound estimate for residency in one dwelling [RAGS, 1989]. The cancer risk
level (1 E-04) employed herein reflects the upper bound of the acceptable risk range [E-()4 - E-
06] established in EPA’s Superfund regulation [Federal Register, 1990]. Practical Quantitation
Limits (PQLs - the lowest level that can be reliably achieved within specified limits of precision
and accuracy during routine laboratory operating procedures [EPA, 1992]) and anticipated
background levels [ATSDR, 1995] dictated the selection of the risk level at 1 E-04. A more
detailed discussion of this subject can be found in Appendix C.
For non-carcinogenic compounds, airborne contaminant concentration is compared to the
Reference Concentration (RfC). The RfC is an estimate of a chronic exposure concentration for
the human population, including sensitive subpopulations, that is likely to be without an
appreciable risk of deleterious effects during a lifetime [RAGS, 1989]. That comparison (i.e,
chronic exposure concentration/RfC) is called the Hazard Quotient As per EPA guidelines, if
the Hazard Quotient (HQ) is greater than one, there may be concern for potential health effects.
Therefore, for Tier III (clearance level), the benchmark screening level was set at an HQ of 1.
For Tier I, which equates to a sub-chronic exposure scenario, an HQ of 10 was used - in
accordance with EPA’s Hazard Evaluation Handbook [EPA, 1997]. An HQ of 10 accounts for
the fact that chronic toxicity criteria (RfDsZRfCs) are being applied to sub-chronic exposure
scenarios (i.e., exposure not expected to exceed 6 months to one year in duration). Accordingly,
an HQ of 10 was used for non-carcinogens to reflect a similar (i.e., upper bound of 1 year)
exposure duration. Note that contaminants (both non-carcinogens and carcinogens, alike) can
exhibit acute effects from short-term, high-dose exposures. Because the Tier I benchmark levels
are based on subchronic exposure (i.e., 1 year), acute effects from exposures that are below the
benchmark levels would be unlikely. A review of EPA’s draft Acute Exposure Guideline Levels
[EPA,2001a] and California EPA’s (CAL-EPA) Acute Risk Levels demonstrates that the
benchmark levels developed are categorically more stringent than the analogous US EPA and
Cal-EPA acute levels.
7
CITY_21MC1OO_OO8969679
NYC-WTC_000317662
OCR can misread numbers and units. Confirm readings against the page image before using them.