NYC 9/11 Public Portal Document

I I Chemical Reason

I Particulate Matter Ambient monitoring in the WTC area has shown that, since late October, levels of PM 10 and PM 2.5 (Iwo commonly measured inhalable PM sizes) have been

i (PM) below EPA’s level of concern for the ambient air (see Appendix B), indicating that there is no continuing source .of PM entering homes and offices. EPA’s Environmental Data Trend Report World Trade Center, 9/11/01 - 4/24/02 [EPA, 2002a] concluded that PM 2.5 and PM 10 appear to have returned to levels of a I steady background state. Refractory Ceramic fiber-containing materials are not expected to be present in the WTC I Ceramic Fibers buildings, as they are mainly used in industrial high temperature applications. Limited sampling conducted by NYCDOH, 2002 did not indicate any ceramic (RCF) fibers in four indoor air samples analyzed by scanning electron microscopy I Mold (SEM). Mold was not directly associated with the WTC collapse. However, it may have

I resulted from the combination of water damage and inoperable HVAC systems. Guidelines for identifying and removing mold are provided through a NYCDOH website (see Appendix A).

Setting Benchmarks for the Contaminants of Potential Concern (COPCs)

A tiered approach was used to evaluate the health risks posed by contaminants that might be present in the indoor enviroiunent (air and settled dust). For each COPC, tliree levels were

I established:

Tier I Level above which, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), aggressive clean-up action should be taken expeditiously along with follow-up sampling to confirm attainment of Tier HI level

I Tier n Range where diligent cleaning should continue, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), with follow­

I Tier DI up sampling to confirm attainment of Tier HI level

Level below which the risk is negligible or consistent with the New York City

I background level found in the aforementioned Background Study ( see Introduction).

I The following hierarchal approach was employed for developing benchmark values: l)Use of relevant and appropriate environmental standards/regulations; 2) Calculation of risk-based benchmarks using EPA risk assessment guidance; and, 3) Adaptation of occupational standards

10

I CITY_21MC100_006740994

NYC-WTC_000319985

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319985Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →