NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
NYC-WTC_000320385–000320529OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
■ t
Chemical Reason Refractory Ceramic fiber-containing materials are not expected to be present in the WTC Ceramic buildings, as they are mainly used in industrial high temperature applications. Fibers Limited sampling conducted by NYCDOH, 2002 did not indicate any ceramic (RCF) fibers in four indoor air samples analyzed by scanning electron microscopy (SEM). Mold Mold was not directly associated with the WTC collapse. However, it may have resulted from the combination of water damage and inoperable HVAC systems. Guidelines for identifying and removing mold are provided through a NYCDOH website (see Appendix A).
Setting Benchmarks for the Contaminants of Potential Concern (COPCs)
A tiered approach was used to evaluate the health risks posed by contaminants that might be present in the indoor environment (air and settled dust). For each COPC, three levels were established:
Tier I Level above which, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), aggressive clean-up action should be taken expeditiously along with follow-up sampling to confirm attainment of Tier III level
Tier II Range where diligent cleaning should continue, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), with follow up sampling to confirm attainment of Tier III level
Tier III Level below which the risk is negligible or consistent with the New York City background level found in the aforementioned Background Study ( see Introduction).
The following hierarchal approach was employed for developing benchmark values: l)Use of relevant and appropriate environmental standards/regulations; 2) Calculation of risk-based benchmarks using EPA risk assessment guidance; and, 3) Adaptation of occupational standards with additional safety factors. Accordingly, a review of environmental standards/regulations was conducted for each of the six COPCs. As a result of this exercise Tier I screening levels for lead in indoor air and settled dust were set using EPA’s National Ambient Air Quality Standard (NAAQS) and the U.S. Housing and Urban Development’s (HUD’s) standard for floors, respectively. The clearance criteria established in the Asbestos Hazard Emergency Response Act (AHERA, 1986) of 70 structures/mm2 was utilized to evaluate asbestos samples from the ambient air monitoring effort. As detailed in Appendix B, the upper bound estimate for exposure duration to contaminants in the ambient air was one year. However, given the potential for extended exposure in residential dwellings, AHERA was deemed less appropriate to this setting.
11
CITY_21MC100_004053239
NYC-WTC_000320473
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
30 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
43 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242900
Draft section describing selection of contaminants of potential concern.
43 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276613
Attachment A: World Trade Center sampling and ancillaries; document header only.
38 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319976
Contributors list for COPC committee on contaminants at World Trade Center site.
46 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199582
Report prepared by a committee detailing contaminants of concern associated with the World Trade Center site.
38 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242774
Laboratory assessment of contaminants related to World Trade Center dust, prepared by COPC committee participants.
39 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
63 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418482
WTC background study interim final report prepared for FEMA and EPA contractors.
33 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348699
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
46 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
44 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000276613
Attachment A: World Trade Center sampling and ancillaries; document header only.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199582
Report prepared by a committee detailing contaminants of concern associated with the World Trade Center site.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317656
Draft COPCs selection and discussion of indoor environmental risks post-9/11.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319976
Contributors list for COPC committee on contaminants at World Trade Center site.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similar indexed content
NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
Similar indexed content
WTC background study interim final report prepared for FEMA and EPA contractors.
Similar indexed content
NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
Similar indexed content
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
Similar indexed content