Chemical Reason
Refractory Ceramic fiber-containing materials are not expected to be present in the WTC
Ceramic buildings, as they are mainly used in industrial high temperature applications.
Fibers Limited sampling conducted by NYCDOH, 2002 did not indicate any ceramic
(RCF) fibers in four indoor air samples analyzed by scanning electron microscopy
(SEM).
Mold Mold was not directly associated with the WTC collapse. However, it may have
resulted from the combination of water damage and inoperable HVAC systems.
Guidelines for identifying and removing mold are provided through a NYCDOH
website (see Appendix A).
Setting Benchmarks for the Contaminants of Potential Concern (COPCs)
A tiered approach was used to evaluate the health risks posed by contaminants that might be
present in the indoor environment (air and settled dust). For each COPC, three levels were
established:
Tier I Level above which, after elimination of potential indoor sources (combustion
by-products, stored chemicals, etc.), aggressive clean-up action should be
taken expeditiously along with follow-up sampling to confirm attainment of
Tier III level
Tier II Range where diligent cleaning should continue, after elimination of potential
indoor sources (combustion by-products, stored chemicals, etc.), with follow
up sampling to confirm attainment of Tier III level
Tier III Level below which the risk is negligible or consistent with the New York City
background level found in the aforementioned Background Study ( see
Introduction).
The following hierarchal approach was employed for developing benchmark values; l)Use of
relevant and appropriate environmental standards/regulations; 2) Calculation of risk-based
benchmarks using EPA risk assessment guidance; and, 3) Adaptation of occupational standards
with additional safety factors. Accordingly, a review of environmental standards/regulations
was conducted for each of the six COPCs. As a result of this exercise Tier I screening levels for
lead in indoor air and settled dust were set using EPA’s National Ambient Air Quality Standard
(NAAQS) and the U.S. Housing and Urban Development’s (HUD’s) standard for floors,
respectively. The clearance criteria established in the Asbestos Hazard Emergency Response Act
(AHERA, 1986) of 70 structures/mm2 was utilized to evaluate asbestos samples from the
ambient air monitoring effort. As detailed in Appendix B, the upper bound estimate for exposure
duration to contaminants in the ambient air was one year. However, given the potential for
extended exposure in residential dwellings, AHERA was deemed less appropriate to this setting.