Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.

NYC-WTC_000145869–000146029

Folder label: “INTERIM FINAL April 2003

Page image
Scanned page image, NYC-WTC_000145968
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Chemical Reason Refractory Ceramic fiber-containing materials are not expected to be present in the WTC Ceramic buildings, as they are mainly used in industrial high temperature applications. Fibers Limited sampling conducted by NYCDOH, 2002 did not indicate any ceramic (RCF) fibers in four indoor air samples analyzed by scanning electron microscopy (SEM). Mold Mold was not directly associated with the WTC collapse. However, it may have resulted from the combination of water damage and inoperable HVAC systems. Guidelines for identifying and removing mold are provided through a NYCDOH website (see Appendix A).

Setting Benchmarks for the Contaminants of Potential Concern (COPCs)

A tiered approach was used to evaluate the health risks posed by contaminants that might be present in the indoor environment (air and settled dust). For each COPC, three levels were established;

Tier I Level above which, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), aggressive clean-up action should be taken expeditiously along with follow-up sampling to confirm attainment of Tier KI level

Tier n Range where diligent cleaning should continue, after elimination of potential indoor sources (combustion by-products, stored chemicals, etc.), with follow­ up sampling to confirm attainment of Tier IH level

Tier in Level below which the risk is negligible or consistent with the New York City background level found in the aforementioned Background Study (see Introduction).

The following hierarchal approach was employed for developing benchmark values: l)Use of relevant and appropriate environmental standards/regulations; 2) Calculation of risk-based benchmarks using EPA risk assessment guidance; and, 3) Adaptation of occupational standards with additional safety factors. Accordingly, a review of environmental standards/regulations was conducted for each of the six COPCs. As a result of this exercise Tier I screening levels for lead in indoor air and settled dust were set using EPA’s National Ambient Air Quality Standard (NAAQS) and the U.S. Housing and Urban Development’s (HUD’s) standard for floors, respectively. The clearance criteria established in the Asbestos Hazard Emergency Response Act (AHERA, 1986) of 70 structures/mm2 was utilized to evaluate asbestos samples from the ambient air monitoring effort. As detailed in Appendix B, the upper bound estimate for exposure duration to contaminants in the ambient air was one year. However, given the potential for extended exposure in residential dwellings, AHERA was deemed less appropriate to this setting.

11

NYC-WTC_000145968

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145968Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132498 · Box DEP Box 54

A DEP report describing ambient outdoor air monitoring for asbestos in Lower Manhattan following the World Trade Center disaster.

Cited alongside this record in an Ask answer

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Cited alongside this record in an Ask answer

NYC-WTC_000142802 · Box DEP Box 06

Document defining indoor air quality terms such as acid aerosols and action levels for radon remediation.

Cited alongside this record in an Ask answer

Compare copies and versions →