NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
NYC-WTC_000320385–000320529OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
In cases where appropriate standards did not exist (e.g., asbestos), risk-based criteria were developed using established EPA risk assessment methods: for indoor air, methods described in EPA’s “Risk Assessment Guidance for Superfund” [RAGS, 1989] were used; for settled dust, EPA Region Ill’s “Wipe Sample Assessment” guidance was utilized with modifications (see Appendix D). The risk-based criteria reflect the most current toxicity criteria (Cancer Slope Factors and RfDs/RfCs) on EPA’s Integrated Risk Information System (IRIS), which is a regularly updated (quarterly), online database that reports chemical toxicity reference values and information on human health effects that may result from exposure to chemicals in the environment.
For contaminants that lacked IRIS verified toxicity criteria, occupational standards were employed. Additional safety factors were added to account for higher exposure and greater sensitivity within the general population.
The clearance criteria paradigm described above is pathway and chemical specific. Accordingly, the benchmarks for each COPC do not account for multimedia and multiple chemical exposure.
Individual sampling results that exceed benchmark values should not be interpreted to represent the occurrence of an adverse health effect. Because benchmark levels assume continuous exposure for an extended duration, the average of the measured concentrations is more appropriate for evaluating risk than individual measurements. Consequently, isolated individual values above the benchmark level may not necessarily be indicative of a hazard.
Developing Risk-Based Criteria for Indoor Air
For carcinogenic compounds, the benchmarks were set so that a local resident’s lifetime risk of developing cancer from exposure to WTC-related contaminants would not exceed a one-in-ten- thousand probability (1x10“*) above the resident’s background risk without this exposure. The amount of time that residents and office workers were exposed to WTC-related contaminants is unknown. To be conservative, the Tier I screening level was chosen to be protective of a resident who may have been exposed to WTC-related contaminants for one year. The Tier III clearance level was chosen to be protective of a resident who is exposed to WTC-related contaminants for 30 years, which is the upper-bound estimate for residency in one dwelling [EPA, 1989]. Cancer risk from less-than-lifetime inhalation exposure is given as:
Risk = LAC * UR
where LAC is the air concentration averaged over a lifetime, calculated as: AC * [EF*ED/LT], where AC is the average air concentration during the period of exposure (pg/m^), EF is the exposure frequency (days/year), ED is the exposure duration (years), LT is lifetime (days), and UR is the unit risk factor, expressed in units of 1/concentration.
The following table lists the input parameters and numerical values (along with a brief explanation) used in this procedure. (See Appendix D for equations and a more detailed discussion).
12
CITY_21MC100_004053240
NYC-WTC_000320474
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
33 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
30 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
43 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242900
Draft section describing selection of contaminants of potential concern.
43 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276613
Attachment A: World Trade Center sampling and ancillaries; document header only.
38 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319976
Contributors list for COPC committee on contaminants at World Trade Center site.
46 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199582
Report prepared by a committee detailing contaminants of concern associated with the World Trade Center site.
38 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242774
Laboratory assessment of contaminants related to World Trade Center dust, prepared by COPC committee participants.
39 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
63 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418482
WTC background study interim final report prepared for FEMA and EPA contractors.
33 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348699
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
46 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
44 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199582
Report prepared by a committee detailing contaminants of concern associated with the World Trade Center site.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276613
Attachment A: World Trade Center sampling and ancillaries; document header only.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348649
COPC committee report on World Trade Center contaminants with multi-agency authors.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242989
COPC committee reporting contributors for WTC-related contaminant list.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similar indexed content
NYC-WTC_000318918
Draft EPA/NYC response background report for WTC air sampling, March 2003.
Similar indexed content
WTC background study interim final report prepared for FEMA and EPA contractors.
Similar indexed content
NYC-WTC_000301612
Draft report prepared for FEMA on WTC indoor air; authoring agency EPA Region 2.
Similar indexed content
COPC committee report with contributors from EPA, NYC DEP, and state agencies.
Similar indexed content