NYC 9/11 Public Portal Document
EM 1110-2-3800
APP B
1 Mar 72
of explosives in blast holes having a slope flatter than one
on one-third shall be reduced progressively with the
flattening of slope. The depth of stemming above the explo
sive will be kept to a minimum and shall not exceed one-
fourth of blast hole depth. Stemming may be required
between each explosive charge in areas where rock contains
open, weathered, or clay-filled seams, joints or faults.
d. Structures. - Excavation of slopes, faces and
shapes in the foundation for structures may necessitate, in
addition to presplit blasting, the use of full hole decking,
limitation on the depth of blast holes, and a limitation on the
width of blast area adjacent to final surfaces to prevent
structural damage to rock beyond the excavation lines. The
method and type of blast hole decking and hole spacing will
be determined by results which are satisfactory to the Con
tracting Officer.
Berms, Benches, Faces and Structural Forms. -
Where a berm, bench or other horizontal surface superim
poses a vertical or sloped surface, excavation to line and
grade of the horizontal surface shall be completed prior to
starting excavation of the vertical or sloped surfaces in
order to prevent loss of the berm shoulder or damage to the
underlying rock face. Blast holes shall not be drilled to a
depth greater than 2 feet below- the design grade of a berm.
Drilling and blasting lift depths in confined shapes or fea
tures shall be limited from one-half to two-thirds the exca
vation width unless otherwise approved by the Contracting
Officer.
f. Final Grades and Excavation Lines. - When exca
vation has progressed to within 15 feet of the final grade or
lines of required excavation against which concrete is to be
placed, drilling and blasting shall be limited to two-thirds
of the remaining depth of excavation except that when 5 feet
or less of rock remains to be excavated, blasting may be
permitted to final grade if it can be demonstrated that no
damage will result to the foundation. Blast holes larger
than 3-1/2 inches in diameter shall not be drilled closer
than 5 feet to a horizontal or near horizontal grade or within
15 feet of a vertical or near vertical face. Whenever, in the
opinion of the Contracting Officer, further blasting may in
jure the rock upon or against which concrete is to be placed,
the use of explosives sl^ll be discontinued and the excavation
B-4
CITY_21MC100_0 12669748
NYC-WTC_000435978
OCR can misread numbers and units. Confirm readings against the page image before using them.