NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 145 pages

Army blasting manual excerpt, 1972

Machine-extracted title · confidence 22%

Publishers’ manual excerpt on blasting for surface excavations.

NYC-WTC_000435845–000435989
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EM 1110-2-3800 APP B 1 Mar 72

shall be completed by hand methods and/or pneumatic tools, by wedging, barring, picking or other approved methods exclusive of explosives.

1-3. Blasting Specification for Structure Area (in Limestone), Stockton Dam.

SECTION B2. EXCAVATION

B2-05. Spillway-Powerhouse Area Excavation, a. General. (1) Spillway-powerhouse area is identified as the areas which are prepared for the concrete structure and includes the approach and outlet channel.

(2) Structure area is identified as that portion of the spillway-powerhouse area from dam station 99+84 to dam station 106+48, range 0+90 upstream to range 4+12 downstream.

B2-08. I^neSj_Grade£,,_and^_Tolerance_s. a. General. Un­ less otherwise specified, all excavation shall be completed to the lines and grades shown on the drawings.

b. “A“ and “B*’ lines as shown on the drawings indicate the maximum and minimum limits for “Bearing Surfaces** and “Special Surfaces.’* No material will be per­ mitted to remain inside the “A** lines.

c. Tolerances. (1) “Special Surfaces*’ are pre- split rock surfaces (except 1 on 1.5 spillway apron slope) against which concrete is to be placed. The tolerances are the “A” lines to “B** lines.

(2) “Bearing Surfaces** are all surfaces under con­ crete structures which are not defined as “Special Surfaces.” Tolerances are the “A** lines to “B** lines.

(3) Pre split Surfaces (Other than *‘Special Sur­ faces**) . Tolerances from the surfaces shown on the drawings shall not exceed three feet measured horizon­ tally, however, the maximum horizontal tolerance between adjacent presplit holes shall not exceed twelve inches.

B-5

CITY_21MC100_0 12669749

NYC-WTC_000435979

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000435979Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →