NYC 9/11 Public Portal Document
EM 1110-2-3800
1 Mar 72
weaker rocks with somewhat larger values for the stronger rocks. If
controlled tests at a given site are not possible, it is recommended that
ground vibrations be kept below 20 ips to prevent damage to rock walls
of underground openings near blasting operations.
(11) A particle-velocity damage criterion for massive monolithic
concrete structures, such as bridge piers, concrete foundations, con
crete dams, and concrete tunnel linings, can be estimated from average
physical properties of concrete and the relation
V = -S-
pc
where
V = particle velocity for failure, fps
O' = failure tensile strength, psi
, lb sec
p = mass density, ----- 7-----
ft
c = propagation velocity, fps
2
For example, if 0- = 600 psi, p = lb/ft— 4.3, and c = 15,000 fps,
32.2 ft/sec*^
then V = 16 ips. Thus, an estimated safe vibration level for concrete
structures would be about 10 ips.
(12) As the safe vibration levels for underground rock structures
and massive concrete structures have been inferred from physical prop
erty data, it is reconnmended that these values be used with caution by
approaching these safe levels gradually. Thus, instrumentation should
be used to determine the vibration levels at the structures as the scaled
distance from the blast is reduced.
b. Recording Equipment.
(1) Ground vibrations resulting from blasting are usually mea
sured by means of either a displacement or velocity seismograph.
These instruments are usually self-recording and can be purchased as
a complete unit. However, it is also possible to use displacement gages,
velocity gages, or accelerometers with appropriate amplifiers and
recorders.
(2) Displacement seismographs consist of three mutually perpen
dicular pendulums. Magnification of the displacement, by means of
7-11
CITY_21MC100_012669724
NYC-WTC_000435954
OCR can misread numbers and units. Confirm readings against the page image before using them.