NYC 9/11 Public Portal Document
EM 1110-2-3800
1 Mar 72
optical lever arms, is usually fixed at some value between 25 and 75.
The displacement seismograph is generally mounted on three leveling
screws that rest on the ground or floor of a structure, and the center
of gravity of the instrument is above the level of the surface on which
the instrument rests. A permanent trace of the ground displacement
as a function of time is made on 2- to 3-in.-wide photographic paper
traveling at a speed of 4 to 5 ips. The useful frequency range is from
about 5 to 50 cps; the dynamic recording range, which is the ratio of
maximum signal deflection to minimum readable deflection, is about 20,
and the maximum acceleration allowable is approximately 0.2 g.^5,46
For a sinusoidal vibration of frequency f , the relation between peak
acceleration a and peak displacement u is
a = 4ir2f^ u
Thus, the allowable range of displacement that can be recorded de
pends upon the frequency of the vibration. Displacement seismographs
can be used to measure the peak particle velocity v of the ground
motion. The maximum slope of the displacement-time record is the
peak particle velocity. If sinusoidal vibrations are assumed, the parti
cle velocity can be calculated from
V = 2nfu
(3) As damage criteria are usually based on particle velocity, it
is recommended that particle velocity be measured directly rather than
be inferred from displacement or acceleration. Velocity seismographs
for recording vibration from blasting consist of three mutually perpen
dicular coils free to move in a magnetic field. These are mounted in a
box, which may be buried in the ground or placed on the surface of the
ground or floor of a structure. Associated with the seismometer box
is another box containing amplifiers, galvanometers, a multiple
channel paper recorder, and a d-c power supply. The sensitivity of
these seismographs is adjustable in the range from 20 to 0.2 in. of
record motion per 1 ips ground motion, and their useful frequency range
is from 2 to 300 cps. The recording paper speed is about 4 ips. Ve
locity seismographs also have a greater dynamic range and a better
frequency range than the displacement type seismographs. Because the
seismometer box can be buried in the ground, the limitation of the
0.2-g level inherent in displacement seismographs is not applicable.
c. Propagation of Ground Vibrations.
(1) Charge size per delay interval and distance from the blast are
7-12
CITY_21MC100_0 12669725
NYC-WTC_000435955
OCR can misread numbers and units. Confirm readings against the page image before using them.