EM 1110-2-3800 1 Mar 72

optical lever arms, is usually fixed at some value between 25 and 75. The displacement seismograph is generally mounted on three leveling screws that rest on the ground or floor of a structure, and the center of gravity of the instrument is above the level of the surface on which the instrument rests. A permanent trace of the ground displacement as a function of time is made on 2- to 3-in.-wide photographic paper traveling at a speed of 4 to 5 ips. The useful frequency range is from about 5 to 50 cps; the dynamic recording range, which is the ratio of maximum signal deflection to minimum readable deflection, is about 20, and the maximum acceleration allowable is approximately 0.2 g.^5,46 For a sinusoidal vibration of frequency f , the relation between peak acceleration a and peak displacement u is

a = 4ir2f^ u

Thus, the allowable range of displacement that can be recorded de­ pends upon the frequency of the vibration. Displacement seismographs can be used to measure the peak particle velocity v of the ground motion. The maximum slope of the displacement-time record is the peak particle velocity. If sinusoidal vibrations are assumed, the parti­ cle velocity can be calculated from

V = 2nfu

(3) As damage criteria are usually based on particle velocity, it is recommended that particle velocity be measured directly rather than be inferred from displacement or acceleration. Velocity seismographs for recording vibration from blasting consist of three mutually perpen­ dicular coils free to move in a magnetic field. These are mounted in a box, which may be buried in the ground or placed on the surface of the ground or floor of a structure. Associated with the seismometer box is another box containing amplifiers, galvanometers, a multiple­ channel paper recorder, and a d-c power supply. The sensitivity of these seismographs is adjustable in the range from 20 to 0.2 in. of record motion per 1 ips ground motion, and their useful frequency range is from 2 to 300 cps. The recording paper speed is about 4 ips. Ve­ locity seismographs also have a greater dynamic range and a better frequency range than the displacement type seismographs. Because the seismometer box can be buried in the ground, the limitation of the 0.2-g level inherent in displacement seismographs is not applicable.

c. Propagation of Ground Vibrations.

(1) Charge size per delay interval and distance from the blast are

7-12

CITY_21MC100_0 12669725

NYC-WTC_000435955

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000435955Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →