NYC 9/11 Public Portal Document
EM 1110-2-3800
1 Mar 72
the two most important parameters that determine the vibration levels
produced in the ground by multiple-hole quarry blasting. Other vari
ables such as burden, spacing, hole depth, hole size, stemming height,
and type of explosive have only a minor effect upon the vibration level
and in quarry blasting can be neglected.
(2) Controlled tests to study the vibration levels from instanta
neous and millisecond-delayed blasts demonstrated that the vibration
level in the ground was dependent on the charge weight per delay inter
val and not on the total charge weight for millisecond-delay blasts.^^
An increase in the number of delay intervals does not affect the vibra
tion level provided that the delay interval is greater than 8 msec and
the charge weight per delay remains constant.
(3) Normally, for spherical or concentrated charges, seismic
effects in the ground would be expected to scale in proportion to the
cube root of the charge weight. However, for quarry blasts variations
in the charge size per delay interval are obtained by changing hole size
and the number of holes per delay interval, with the charge length re
maining practically constant. This method of changing charge size per
delay interval is more nearly represented by square root scaling. A
general propagation relation for peak particle velocity as a function of
distance and charge size per delay interval has been established‘S® as
. 1/2
V = H (D/W ' )
where
V = peak particle velocity of any one component of vibration
(radial, transverse, or vertical), ips
D = distance from blast area to point of measurement, ft
W = charge weight per delay interval, lb
H, (3 = constants (e below).
The quantity (D/W^^^) is the scaled distance.
(4) A typical example of data for peak particle velocity versus
scaled distance for one particular site is shown in Fig. 7-5. Note that
the data for each component of peak particle velocity tend to group
about straight lines on log-log coordinates and that the standard devi
ations of the data about these straight lines are less than ±50 percent
of the mean values. If one assumes that the data given in Fig. 7-5 are
representative of all future blasts at this particular site, the probability
of having a blast that produces a vibration level greater than 2 ips at a
7-13
CITY_21MC100_012669726
NYC-WTC_000435956
OCR can misread numbers and units. Confirm readings against the page image before using them.