Facade cleaning reports, 1619 Third Ave condo, 2002

Machine-extracted title · confidence 45%

Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.

NYC-WTC_000420968–000420986
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Management Solutions of NY, Inc. 67- Woodside Avenu-p, Btiaccliff Manor, NY 10510 • Tcl 914 762 6.533 - Fax 914 762 3578

October 5, 2001

Mt. Bob Vaccarello Tel: (212)534-7771 R y Management Fax; (212)534-6140 1619 3"^ Avenue NYC, NY 10128

Re: Environmental Sampling at Hudson View East Condominiums 250 South End Avenue

Dear Mr, Vaccarello;

Following the WTC terrorist attack, EMS of NY was retained by your lirm to conduct air testing within the hallways and select apartments, wipe/debris sampling within apartments that contained visible debris and water sampling for E. Coli, an indicator of waler quality.

The information below details the action.^ undertaken, along with providing an explanation of the processes and applicable standards for the testing performed.

Airborne Asbestos Testing: fhc airborne fiber testing was performed within the common hallways and select apartment units within the buildings, fhc purpose of performing the testing was to determine whether elevated concentrations of asbestos, above cun ent regulatory standards are present within the areas tested.

Current acceptable levels set forth by the Environmental Protection Agency i.s an airborne concentration of 70 structures per square millimeter of air (s/mm^). I'he standard of 70 s/mm^ is used to determine whether airborne levels following an abatement project are acceptable for human occupancy. If the concentration exceeds 70 s/nun^, the affected area is compared to background levels prior to determine acceptability. levels below 70 s/mm2 arc deemed acceptable for reoccupancy according to NYC DEP,

Asbestos Debris/Dust Testing; The testing in this .situation was peifomied within select hallway.s whereby accimiulated dust/debns was identified. The purpose of lesling the debris material was to determine whether asbe.stos was present and if so, could this material become airborne, especially if cleaning activities commence using non-specialized equipment.

In evaluating the results, asbestos was reported as absent or present, liic absence of asbestos .suggests that no a.sbe.stos fibers were identified and that if the air data in and around the building was also less than 70 s/miir, then the likelihood of the results remaining below maximum acceptable levels.

<in ........... ...

hazard identificaEion risk management ® i m p a c r assessment 02600

CITY_DEP_WORBY_CANNATA_SUBP_000023185

NYC-WTC_000420971

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420971Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000230980

Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.

Similar indexed content

Compare copies and versions →