NYC 9/11 Public Portal Document
Environmental Management Solutions of NY, Inc.
67- Woodside Avenu-p, Btiaccliff Manor, NY 10510 • Tcl 914 762 6.533 - Fax 914 762 3578
October 5, 2001
Mt. Bob Vaccarello Tel: (212)534-7771
R y Management Fax; (212)534-6140
1619 3"^ Avenue
NYC, NY 10128
Re: Environmental Sampling at
Hudson View East Condominiums 250 South End Avenue
Dear Mr, Vaccarello;
Following the WTC terrorist attack, EMS of NY was retained by your lirm to conduct air testing
within the hallways and select apartments, wipe/debris sampling within apartments that
contained visible debris and water sampling for E. Coli, an indicator of waler quality.
The information below details the action.^ undertaken, along with providing an explanation of the
processes and applicable standards for the testing performed.
Airborne Asbestos Testing: fhc airborne fiber testing was performed within the common
hallways and select apartment units within the buildings, fhc purpose of performing the testing
was to determine whether elevated concentrations of asbestos, above cun ent regulatory standards
are present within the areas tested.
Current acceptable levels set forth by the Environmental Protection Agency i.s an airborne
concentration of 70 structures per square millimeter of air (s/mm^). I'he standard of 70 s/mm^ is
used to determine whether airborne levels following an abatement project are acceptable for
human occupancy. If the concentration exceeds 70 s/nun^, the affected area is compared to
background levels prior to determine acceptability. levels below 70 s/mm2 arc deemed
acceptable for reoccupancy according to NYC DEP,
Asbestos Debris/Dust Testing; The testing in this .situation was peifomied within select
hallway.s whereby accimiulated dust/debns was identified. The purpose of lesling the debris
material was to determine whether asbe.stos was present and if so, could this material become
airborne, especially if cleaning activities commence using non-specialized equipment.
In evaluating the results, asbestos was reported as absent or present, liic absence of asbestos
.suggests that no a.sbe.stos fibers were identified and that if the air data in and around the building
was also less than 70 s/miir, then the likelihood of the results remaining below maximum
acceptable levels.