Letter from RY Management regarding testing, 250 South End Avenue

Machine-extracted title · confidence 95%

Correspondence enclosing independent and agency test reports for the residential condominium at 250 South End Avenue.

NYC-WTC_000121056–000121060

Folder label: “250 SOUTH END AVENUE Block: 16 Lot: 7503 BIN: 1065089 Hudson View East Condominium

Page image
Scanned page image, NYC-WTC_000121059
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ENVIRONMENTAL MANAGEMENT SOLUTIONS OF NY, INC. 67 Woodside Avenue, Briarcl iff Manor, NY 10510 • Tel 914 762 6333 • Fax 914 762 5578

October 5, 2001

Mr. Bob Vaccarello Tel: (212) 534-7771 R Y Management Fax: (212) 534-6140 1619 3rc1 Avenue NYC, NY 10128

Re: Environmental Sampling at Hudson View East Condominiums — 250 South End Avenue

Dear Mr. Vaccarello:

Following the WTC terrorist attack, EMS of NY was retained by your firm to conduct air testing within the hallways and select apartments, wipe/debris sampling within apartments that contained visible debris and water sampling for E. Coll, an indicator of water quality.

The information below details the actions undertaken, along with providing an explanation of the processes and applicable standards for the testing performed.

Airborne Asbestos Testing: The airborne fiber testing was performed within the common hallways and select apartment units within the buildings. The purpose of performing the testing was to determine whether elevated concentrations of asbestos, above current regulatory standards are present within the areas tested.

Current acceptable levels set forth by the Environmental Protection Agency is an airborne concentration of 70 structures per square millimeter of air (s/mm). The standard of 70 s/m►n2 is used to determine whether airborne levels following an abatement project are acceptable for human occupancy. If the concentration exceeds 70 s/mm2, the affected area is compared to background levels prior to detennine acceptability. Levels below 70 s/mm2 are deemed acceptable for reoccupancy according to NYC DEP.

Asbestos Debris/Dust Testing: The testing in this situation was performed within select hallways whereby accumulated dustldebris was identified. The purpose of testing the debris material was to determine whether asbestos was present and if so, could this material become airborne, especially if cleaning activities commence using non-specialized equipment.

In evaluating the results, asbestos was reported as absent or present. The absence of asbestos suggests that no asbestos fibers were identified and that if the air data in and around the building was also less than 70 s/mm2, then the likelihood of the results remaining below maximum acceptable levels.

hazard identification • risk management impact assessment

NYC-WTC 000121059

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121059Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121065 · Box DEP Box 48

Summary of air and dust sampling results collected from private residences and common areas at 250 South End Avenue.

Cited alongside this record in an Ask answer

Compare copies and versions →