NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 37/17 BATTERY PLACE; Block: 15; Lot: 7501; BIN: 1082634; 1 West Street, 2-26 Washington Street, 1 Western Union Plaza
Document / 51 pages

Invoice with assessment summary, 17 Battery Place, Apr 2002

Machine-extracted title · confidence 95%

Invoice enclosing bulk sample results, air monitoring data, and cleanup summaries for 17 Battery Place.

NYC-WTC_000105155–000105205

Folder label: “17 BATTERY PLACE; Block: 15; Lot: 7501; BIN: 1082634; 1 West Street, 2-26 Washington Street, 1 Western Union Plaza

Page image
Scanned page image, NYC-WTC_000105194
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document APR-01-2002 11:57 PM P.09

ENVIRONMENTAL MANAGEMENT SOLUTIONS OF NY,INC. 67 Woodside Avenue, Briarcliff Manor, NY 10510 • Tel 914 762 6333 • Fax 914 762 5578

November 6, 2001

Mr. Sid Moskowitz Newmark Construction Services, LLC 594 Broadway New York, NY 10017

Re: Air Sample Results from 17 Battery Street, NYC

Dear Mr. Budabin:

Following the collapse of the World Trade Center Towers and surrounding properties, EMS of NY was retained by your office to perform baseline sampling within the building to determine if airborne asbestos was present.

On November 1, 2001 EMS tested representative floors and subjected the samples to analysis via Transmission Electron Microscopy (TEM). TEM analysis is deemed state of the art and is able to distinguish between asbestos and non-asbestos fibers.

The results that were obtained indicated that at the time of testing no asbestos was detected.

Current acceptable levels as set forth by the Environmental Protection Agency (EPA) are set at 70 s/mm2. The standard of 70 s/mm2 is used to determine whether background levels or airborne levels following an abatement project are acceptable for human occupancy. if the concentration exceed 70 s/mm2, then additional testing along with clean-up and possible protective equipment should be initiated

Overall, based upon the sampling results, the air quality in regards to asbestos, according to EPA standards, is acceptable.

If you have any questions or require additional information, please contact me.

Sin rely, avc

Marc Rutstein Vice President.

hazard identification • risk management • impact assessment APR-01-2002 12:00 96i P.09

NYC-WTC 000105194

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105194Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →