ENVIRONMENTAL MANAGEMENT SOLUTIONS OF NY, INC.
X67 Woodside Avenue, Briarcliff Manor, NY 10510 • Tel 914 762 6333 • Fax 914 762 5578
October 11, 2001
Mr. Michael Schenker Tel: (212) 529-5688 x 280
Andrews Building Corporation Fax: (212) 529-7987
666 Broadway
New York, NY 10012
Re: Air Sample Results:
25 Ann Street, NYC
Dear Mr. Schenker:
Following the collapse of the World Trade Centers and associated properties, EMS was retained
by your office to perform baseline sampling within the-building to determine if airborne asbestos
was present.
EMS tested representative floors and subjected the samples to analysis via Transmission Electron
Microscopy (TEM). TEM analysis is deemed state of the art and is able to distinguish between
asbestos and non-asbestos fibers.
The samples were determined to be overloaded with particulate matter from the debris release
associated with the collapse of the WTC buildings and the on-going cleaning operations. For
subsequent sample collection a lower total volume was collected at a lower flow rate in an effort
to minimize the likelihood of sample overload. In order to determine if asbestos was present, the
laboratory performed sonication and filtering and then analyzed the samples using TEM
methodologies.
No asbestos was detected in any of the sonicated samples, meaning that at the time of sample
collection, airborne asbestos was not captured onto the filter media.
Current acceptable levels as set forth by the Environmental protection Agency are 70 s/mni2.
The standard of 70 s/mm2 is used to determine whether background levels of asbestos or airborne
levels of asbestos following an abatement project are acceptable for human occupancy. If the
concentration exceed 70 s/mm2, then additional testing along with clean-up and possible
protective equipment is recommended.
Overall, based upon the sampling results, the air quality specifically in regards to asbestos, is
acceptable based on EPA standards at the time of sample collection. It is recommend that the
building be sampled again in the future to determine if any changes occur now that a baseline has
been established.
If you have any questions or require additional information, please contact me.
Sin erel
rc Rutstein
Vice President