NYC 9/11 Public Portal Document APR-01-2002 11:54 PM P. 02

ENVIRONMENTAL MANAGEMENT SOLUTIONS OF NY, INC. 67 Woodside Avenue, Briarcliff Manor, NY 10510 • Tel 914 762 6333 • Fax 914 762 5578

September 25, 2001

Mr. Sid Moskowitz Newmark Construction Services, LLC 594 Broadway New York, NY 10017

Re: Air Sample Results: 17 Battery Street New York, NY

Dear Mr. Budabin:

Following the collapse of the World Trade Centers and associated properties, EMS was retained by your office to perform baseline sampling within the building to determine if airborne asbestos was present.

On September 25, 2001 EMS tested representative floors and subjected the samples to analysis via Transmission Electron Microscopy (TEM). TEM analysis is deemed state of the art and is able to distinguish between asbestos and non-asbestos fibers. It is important to note that during the testing, the building HVAC was not operating and had not been operating prior to our testing. Therefore, any debris within the system or building would likely have settled and not remain airborne. Upon turning on the system, the results could be considerably different and may warrant additional sampling.

The results that were obtained indicated that at the time of testing no asbestos was detected.

Current acceptable levels as set forth by the Environmental protection Agency are set at 70 slmm2. The standard of 70 s/mm2 is used to determine whether background levels or airborne levels following an abatement project are acceptable for human occupancy. If the concentration exceed 70 s/mm2, then additional testing along with clean-up and possible protective equipment should be initiated.

Overall, based upon the sampling results, the air quality in regards to asbestos, according to EPA standards, is acceptable. Once again, since testing was not performed under "normal" conditions, the airborne concentrations could change once the building returns to normal operation and air movement along with building activities resume.

If you have any questions or require additional information, please contact me.

Sincerely, (( IViac 1e- Marc Rutstein Vice President.

hazard identification • risk management • impact assessment 'R-1-2g2 11:57 95`. P.02

NYC-WTC 000105187

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105187Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →