EMS environmental management, air sample results, Oct 2001

Machine-extracted title · confidence 50%

EMS results for air samples post-WTC collapse; TEM analysis noted.

NYC-WTC_000342939
Page image
Scanned page image, NYC-WTC_000342939
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1^;

Environmental Management Soiutions of NY, Inc._________ 67 Woodside Avenue, Briarcliff Manor, NY 10510 • Tel 914 762 6333 • Fax 9 1 4 762 5578

October 11, 2001

Mr. Michael Schenker Tel: (212)529-5688 x280 Andrews Building Corporation Fax: (212)529-7987 666 Broadway New York, NY 10012

Re: Air Sample Results; 25 Ann Street, NYC

Dear Mr. Schenker;

Following the collapse of the World Trade Centers and associated properties, EMS was retained by your office to perform baseline sampling within the-building to determine if airborne asbestos was present.

EMS tested representative floors and subjected the samples to analysis via Transmission Electron Microscopy (TEM). TEM analysis is deemed state of the art and is able to distinguish between asbestos and non-asbestos fibers.

The samples were determined to be overloaded with particulate matter from the debris release associated with the collapse of the WTC buildings and the on-going cleaning operations. For subsequent sample collection a lower total volume was collected at a lower flow rate in an effort to minimize the likelihood of sample overload. In order to determine if asbestos was present, the laboratory performed sonication and filtering and then analyzed the samples using TEM methodologies.

No asbestos was detected in any of the sonicated samples, meaning that at the time of sample collection, airborne asbestos was not captured onto the filter media.

Current acceptable levels as set forth by the Environmental protection Agency are 70 s/mm^. The standard of 70 s/mm" is used to determine whether background levels of asbestos or airborne levels of asbestos following an abatement project are acceptable for human occupancy. If the concentration exceed 70 s/mm\ then additional testing along with clean-up and possible protective equipment is recommended.

Overall, based upon the sampling results, the air quality specifically in regards to asbestos, is acceptable based on EPA standards at the time of sample collection. It is recommend that the building be sampled again in the future to determine if any changes occur now that a baseline has been established.

If you have any questions or require additional information, please contact me.

Sincerely,..-

Marc Rutstein Vice President

hazard identification risk management impact assessment

CITY_21MC100_003008706

NYC-WTC_000342939

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342939Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →