NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
6 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗EMSNY environmental monitoring report describing sampling events and procedures after WTC incidents.
NYC-WTC_000367207
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Environmental Management Solutions of NY, Inc. 6 7 Woodside Avenue, B HIT M.inor, NY lOSlO • Tel 61 i 76 2 6 3 33 • Fax 914 76 2 5 57 8
October 31, 2001
Mr. Robert Vaecarello Tel 212-534-7771 Fax 212-534-6140 R Y Management 1619 3"'' Avenue NYC, NY 10128
Re: Final Comprehensive Report: Hudson View East - 250 South End Avenue
Dear Mr. Vaecarello'
Following the collapse of the World Trade Centers and associated pioperties, EMSNY was retained by your office to perfonn sampling on various dates for specific purposes as desenbed below This report details the specific sampling performed on each date and includes the general findings A comprehensive spreadsheet is also included that details all sampling by date, the type of sampling and the results
September 24, 2001 Air sampling was performed throughout the building m common areas only The TEM (Transnussion Electron Microscopy) lesiilis reported by the laboratory were equal to or less than 26 67 stnicturcs per square millimeter The Clearance Criteria set forth by New York City Department of Environmental protection is 70 structure.s per square milliineter.
September 27, 2001: Water sampling was performed and analyzed for potability. Neither E-Coli nor Coliform was detected
September 28, 2001 Bulk sampling of specific apartments to determine whether the dust/debri.s contained asbestos. Analysis of five samples determined the presence of asbestos in Iwo samples. EMSNY recommend.s that all dust/debris be deemed asbestos- contanunated and treated accordingly given the magnitude of the event and the heterogeneous nature of the material.
October 17,2001. Air sampling was performed iii random apartments throughout the building. The results by TEM analysis indicated that airborne asbestos was not detected at the time of testing.
If you have any questions or require additional information, please contact me.
Sincerely, b Marc Rutstein t— Reviewed by Marco Pedo/ie / \ \ Vice President PhD, MPH, CSP, CET £ / V bMARQfiXPEDOHE.J
hazard identification risk, management impact assessment
CITY_DEP_WORBY_CANNATA_SUBP_000004030
NYC-WTC_000367207
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
6 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
6 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342939
EMS results for air samples post-WTC collapse; TEM analysis noted.
3 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000231403
Document establishing the chain of custody for an asbestos assessment, bulk sampling, and air monitoring report at a building on Liberty Avenue.
4 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230955
Letter notifying the DEP of a change in property management for a building on Murray Street and providing updated contact information.
3 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409062
Air TEM analysis report concluding no asbestos detected.
2 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121056
Correspondence enclosing independent and agency test reports for the residential condominium at 250 South End Avenue.
5 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
4 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000112085
Final report from GPS Environmental Consultants confirming the World Financial Center North Tower is cleared for re-occupancy following asbestos cleanup.
4 shared non-person entities · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
4 shared non-person entities · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
4 shared non-person entities · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150163
Internal memo draft addressed to the Commissioner regarding environmental compliance actions and correspondence drafts dated October 15, 2001.
4 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000121061
Laboratory report from EMSNY detailing air sampling results for 250 South End Avenue conducted in September 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121056
Correspondence enclosing independent and agency test reports for the residential condominium at 250 South End Avenue.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
Similar indexed content
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
Similar indexed content
NYC-WTC_000342939
EMS results for air samples post-WTC collapse; TEM analysis noted.
Similar indexed content
Correspondence enclosing independent and agency test reports for the residential condominium at 250 South End Avenue.
Similar indexed content
NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
Similar indexed content