Asbestos Abatement
13. The Contractor shall not allow accumulation of scrap, debris, waste
material, and other items not required for use in this work, When asbestos
contaminated waste must be kept on the work site overnight or longer, it
shall be double bagged and stored in tightly closed and sealed fiber drums,
placed inside or outside the contaminated area.
14. At least twice a week (more if necessary), the Contractor shall completely
remove all scrap, debris and waste material from the job site.
15. The Contractor shall provide adequate storage space for all items awaiting
removal from the job site, observing all requirements for fire protection
and concerns for the environment.
16. All respiratory protection equipment shall be selected from the latest
NIOSH Certified Equipment list.
17. Daily and more often, if necessary, the Contractor shall inspect the Work
Areas and adjoining spaces, and pick u all scrap, debris, and waste
material. Al such items shall be removed to the place designated for their
storage.
18. Weekly, and more often, if necessary, the Contractor shall inspect all
arrangements of materials stored on the site; re-stack and tidy them or
otherwise service them to meet the requirements of these Specifications.
19. The Contractor shall maintain the site in a neat and orderly condition at all
times.
Part 3 - EXECUTION
3.1 WORKER DECONTAMINATION FACILITY
A. Large Asbestos Projects (Small Project Option):
1. Provide a worker decontamination facility in accordance with. Title 15,
Chapter 1, OSHA Standard 29 CFR 1926.1101, 12NYCRR Part 56 and as
specified herein. Unless approved by NYCDEP and the City, worker
decontamination facilities shall be attached to the Work Areas
a) Structure:
(1) Use modular systems or build using wood or metal frame
studs, joists, and rafters placed at a maximum of 16 inches
CAPITAL PROJECT NUMBER PO79201K 02081-54
100: CONTRACT DOCUMENTS REV. May 3,2000
- 54 -100% CONTRACT DOCUMENTS
REV. 0: DATE
CITY_21MC100_006631303
NYC-WTC_000416815