Police Academy asbestos abatement specifications, DDC

Machine-extracted title · confidence 48%

Contract specs for abatement of asbestos-containing materials at Police Academy.

NYC-WTC_000416762–000416866
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Abatement

protective systems such as alarms, sprinklers, locks, etc. The Facility shall ensure no active air handling systems are operating within the Work Area.

F. City will not occupy the portions of the building, in which work is being performed during the entire asbestos removal operation, including completion of clean up.

G. Contractor shall provide a plan for 24 hours job security both for prevention of theft and for barring entry of curious but unprotected personnel into Work Areas.

H. Should the failure of any utility occur, the City will not be responsible to the Contractor for loss of time or any other expense incurred.

I. Facility will be responsible to notify the Contractor of any planned electrical power shutdowns in order to ensure that there are no power interruptions in the negative air pressure systems.

1.12 USE OF BUILDING FACILITIES

A. City shall make available to the Contractor, from existing outlets and supplies, all reasonably required amounts of water and electric power at no charge.

B. Electric power to all Work Areas shall be shut down and locked out except for electrical equipment that must remain in service. Safe temporary power and lighting shall be provided by Contractor in accordance with applicable codes. All power to Work Areas shall be brought in from outside the area through ground-fault interrupter circuits installed at the source. Stationary electrical equipment within the Work Area, which must remain in service, shall be adequately protected, enclosed and ventilated. The Facility will identify all electric lines that must remain in service. Contractor shall protect all lines.

C. Contractor shall provide, at his own expense, all electrical, water, and waste connections, tie-ins, extensions, and construction materials, supplies, etc. All water tie-ins shall be hard piped with polyethylene or copper piping. At the end of each shift. Contractor shall disconnect all hoses within the work zone and place in equipment room of the worker decontamination unit. Contractor shall ensure positive shutoff of all water to Work Area during non-working hours.

D. Utilities:

1. General:

a. All temporary facilities required to be installed, shall be subject to the approval of the Commissioner. Prior to starting the work at any site; specify clearly the temporary locations of facilities preferably with sketches and submit the CAPITAL PROJECT NUMBER PO79201K 02081-30 100: CONTRACT DOCUMENTS REV. May 3,2000 - 30 -100% CONTRACT DOCUMENTS REV. 0: DATE

CITY_21MC100_006631279

NYC-WTC_000416791

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000416791Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

Asbestos, NY DOL reference

NYC-WTC_000441450

Asbestos standards reference page from NY Department of Labor materials.

Similar indexed content

Compare copies and versions →