CHAPTER 1—ASBESTOS CONTROL PROGRAM §1-82
(b) The worker decontamination enclosure system shall consist of a clean
room, a shower room, and an equipment room, in series, separated from each
other by airlocks and from the work area and non-work place by curtained
doors (see Illustrations I & II).
(c) Worker decontamination enclosure systems shall be fully lined utiliz
ing two layers of 6-mil opaque plastic sheeting at a minimum, or the equiva
lent.
(d) When the decontamination enclosure system is constructed outdoors
or in areas with public access it shall be fully framed and plywood sheathed
or equivalent to prevent unauthorized entry. When located outdoors, it shall
be waterproof and windproof.
(e) Prefabricated or trailer decontamination units:
(1) shall at a minimum, have functionality and security equivalent to
constructed decontamination enclosure facilities, and
(2) shall be completely decontaminated prior to removal from the work
site.
(f) The clean room:
(1) shall contain secure crew lockers or shelves, and clean sealable
plastic bags for storage of street clothes, and
(2) shall contain shelves or appropriate facilities for storage of respira
tors, and
(3) shall contain clean disposable clothing, replacement filters for respi
rators, towels and other necessary personal protective equipment, and
(4) shall not be used for storage of tools, equipment or materials, other
than personal protective equipment, nor used as office space, and
(5) shall be equipped with a lockable door to secure the work place
during off-shift hours.
(g) The shower room:
(1) shall contain a minimum of one shower per 8 workers calculated on
the basis of the largest shift, and
(2) shall have shower heads supplied with hot and cold water adjustable
at the shower, and
(3) shall be constructed to ensure against water leakage, and
(4) shall contain liquid bath soap, shampoo and clean, dry towels in
sufficient quantity for each worker for each showering.
(h) Shower water shall be drained, collected and filtered through a system
with at least 5.0 micron particle size collection capability. A system containing
a series of several filters with progressively smaller pore sizes shall be used
to avoid rapid clogging of the filtration system by large particles.