NYC 9/11 Public Portal Document
§1-82 TITLE 15—DEPT. OF ENVIRONMENTAL PROTECTION
(r) Floor drains shall be sealed individually with two layers of 6-mil plastic
sheeting and tape, and then covered as all other floor surfaces. Pits, sumps,
etc., shall be covered with adequate plywood sheeting and secured to floor .
slabs in a manner which prevents a tripping hazard, prior to required
plasticizing.
(s) Elevators running through the work area shall conform to the follow
ing; —
(1) The elevator door, in the work area shall be enclosed with conven
tional 2x4 stud framing, covered with plywood sheeting and sealed at
all edges and seams. The barrier shall be covered and lapped for 8 inches
with two layers of 6-mil plastic sheeting adhered individually with edges
taped for air tightness.
(2) Elevators not remaining in service shall have the fuses removed and
the power switch locked in the open position.
(3) Elevators that remain in operation shall conform to the following
additional procedures to minimize the piston effect that results:
(i) Elevator control shall be modified to bypass the work area.
(ii) A final larger layer of 6-mil plastic sheeting is to be taped airtight
but with slack forming a larger perimeter diaphragm. Air leakage across
the barrier shall be corrected upon discovery, and the elevator shaft shall
be checked for airborne asbestos contamination.
(iii) This system shall be smoke tested daily.
(4) Elevator shafts shall not be used as waste chutes.
(t) Adequate toilet facilities shall be provided in the vicinity of the clean
room external to the work place. Where such facilities do not exist, portable
service shall be provided.
§1-82 Worker Decontamination Enclosure System. The following proce
dures shall be followed during the conduct of abatement activities on large
asbestos projects:
(a) Worker decontamination enclosure systems shall be located outside
the work area and attached to all locations where workers will enter or exit
the work area. One system at a single location for each contained work area
is preferred. These systems may consist of existing rooms outside of the work
area, that offer direct access to the work area and general egress from the
work place. When this situation does not exist, enclosure systems may be
constructed or may consist of prefabricated or trailer units. Adequate heat
and light shall be safely provided.
5824 RCNY 5-31-98
CITY_21MC100_006242978
NYC-WTC_OOO41 1847
OCR can misread numbers and units. Confirm readings against the page image before using them.