§1-45 TITLE 15—DEPT. OF ENVIRONMENTAL PROTECTION
(d) Bulk and air sampling results/reports shall be submitted directly to
the Department upon request -within five calendar days.
§1-45 Action Criteria, (a) When visible emissions occur outside the
■work area, glovebag or tent, or any area air sample has indicated a determi
nant level of fiber concentrations greater than the larger of baseline levels or
0.01 i/cc, or 0.05 ficc for abatement activities which are part of a pre-demoli-
tion abatement activity, work shall stop for inspection.
(1) For large or small asbestos projects, the integrity of barriers, if
disturbed, shall be restored. Clean-up of surfaces outside of the work area
using HEPA vacuums or wet cleaning techniques shall be done prior to
resuming abatement activities.
(2) For glovebag and tent procedures, HVAC systems to or in the work
area shall be shut down and the work area shall be wet cleaned or HEPA
vacuumed until the area air samples indicate the fiber concentration is
below the determinant level. If fiber concentrations remain above the
determinant level for longer than 24 hours, isolation barriers and engineer
ing controls shall be installed and maintained.
(b) Clearance and for reoccupancy criteria. (1) The clearance criteria
shall be applied to each homogeneous work area independently.
(2) For PCM analysis involved in alteration or renovation projects, the
clearance air monitoring shall be considered satisfactory when every sam
ple is less than or equal to 0.01 fZcc or less than the ambient concentration,
whichever is larger.
(3) For PCM analysis involved in pre-demolition abatement activities,
the clearance air monitoring shall be considered satisfactory when every
sample is less than or equal to 0.05 tZcc or less than the ambient concentra
tion, whichever is larger.
(4) Por TEM analysis, the clearance monitoring ■'will be considered
satisfactory if conducted in accordance ■with 40 CFR Part 763, Subpart E,
Appendix A — Section IV — Mandatory Interpretation of Transmission
Electron Microscopy Results to Determine Completion of Response Actions.
(5) Clearance air monitoring results shall be submitted directly to the
Department within 24 hours of request.