NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Indoor environmental quality survey, 9th floor, 2002

Machine-extracted title · confidence 26%

Letter/report about bulk dust/debris sampling on building setbacks for Insignia ESG at a NYC building.

NYC-WTC_000363857–000363858
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

■n ambient group me. NATIONAL HEADQUARTERS

$5 WEST JQw SmSKT Indoor environmental quality surveys rXTH FLOOR Water treatment consulting NEW YORK, NEW YORK IOO18 Asbestos ft lead field services tel; (212) 944-4-615 Regulatory compliance programs PAX: (212) 944-4618 Air, water & soil analytical laboratories WEB: WWW.AMaiENTGROLiP.COM

March 11, 2002

Mr. Steven A. Donahue InsigniaZESG, Inc. One Broadway New York, NY 10004

Re: Exterior Assessment of Possible Building Contamination Project #220282

Dear Mr.Donahue On March 5, 2002 at the request of the Building’s Management (Insignia/ESG), Ambient Group, Inc. collected bulk samples of suspect dust/debris material located on several of the building’s roofi'setbacks The purpose of the sampling was to determine whether the possibility of asbestos contamination occurred to the exterior of the building as a result of the collapse of the World Trade Center. Also a recent visual survey by the New York City Department of Environmental Protection (NYCDEP) indicated that suspect dust was observed on the building’s exterior. Therefore, Ambient was requested to collect appropriate representative samples of the NYCDEP observed suspect materials. A total of four (4) bulk samples were collected of suspect dust/debris material from selected roof/setback levels. All of the samples analyzed indicated the presence of asbestos, in an amount between 0.3% and 2%. All samples were analyzed by Polarized Light Microscopy (NYSDOH ELAP Method 198.1). Based on the above it is recommended that the Building undergo a cleanup of exterior roof/setback surfaces in accordance with the NYCDEP’s roof decontamination procedures (copy attached). Also attached please find a description of the bulk sampling and sample analysis protocols used during this project and the Bulk Sample Laboratory Data Reports for this project. Should you have any questions, please do not hesitate to call Sincerely, 'Signed for Ambient Group, Inc. by.

Jj Cianci, Project Manager

GLEN COVE, NY MIAMI, FL CHICAGO, IL GRANGE, CA

516 609-Of?-■'9 30$ SSo-otet 5^7-55^6 714- Z82-J515

eoo® anilBaoa v uaAsag iet’SStSZTZ YVJ £e:frT ZOOZ/-Z2/E0

CITY_DEP_WORBY_CANNATA_SUBP_000003337

NYC-WTC_000363857

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363857Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →